Preliminary study of fogging process for fixing high-concentration radioactive aerosol 131I contamination in a radiopharmaceutica production unit |
GAO Shuai, QIAO Haitao, ZHANG Jing, HU Pei, SHUAI Hongpeng, YIN Huilong, MA Bingwen |
HTA Co., Ltd., Beijing 102413 China |
|
|
Abstract Objective To prove the feasibility of a Fogging Process in fixing high-concentration radioactive aerosol 131I contamination.Methods High-concentration radioactive aerosol 131I contamination in an 131I-operating glovebox for radiopharmaceutical production was disposed by using fogging and fixing process. The aerosol 131I concentrations were detected and the results were analyzed.Results After a 120 minutes fixing, the 131I contamination in this glovebox reduced from(289 ±9) DAC and (304 ±6) DAC to (21.7 ±2.0) DAC and (26.2 ±1.8) DAC. After a 180 minutes fixing, the 131I contamination in this glovebox reduced from (259 ±10) DAC to (1.80 ±0.18) DAC. These results showed that no aerosol 131I contamination was raised again after 24-hours finishing this task.Conclusion Aerosol 131I concentration in a limited space could be controlled by using a fogging and fixing process, which could reduce the risk of internal exposure of staff. This process could be used by radiopharmaceutical production as an emergency management for dispose high-concentration radioactive aerosol 131I contamination.
|
Received: 11 August 2020
|
|
|
|
|
[1] 李思进. 2018年中国核医学现状普查结果Z/OL]. (2018-09-14)[2020-7-21]. http://chinanm.cma.org.cn/art/2018/9/14/art_1365_23723.html. LI SJ. Results of The National Survey of Nuclear Medicine in 2018[R/OL]. (2018-09-14)[2020-7-21]. http://chinanm.cma.org.cn/art/2018/9/14/art_1365_23723.html. [2] 朱寿彭, 李章. 放射毒理学[M].苏州: 苏州大学出版社, 2004: 259-260. Zhu SP, Li Z. Radiation toxicology[M]. Suzhou: Soochow University Press, 2004: 259-260. [3] 文湘闽, 刘忠恕, 李兴义, 等. 碘[131I]化钠口服液生产线辐射防护安全措施评价[J]. 职业卫生与病伤,2007,22(4):299-300. DOI: 10.3969/j.issn.1006-172X.2007.04.020 Wen XM, Liu ZS, Li XY, et al. Evaluation of the radiation protective measures for the production line of a Sodium 131I oral solution[J]. J Occup Heal Damage, 2007, 22(4): 299-300. DOI: 10.3969/j.issn.1006-172X.2007.04.020 [4] 刘丽波, 陈强. 放射性甲状腺疾病诊断解析[J]. 中国辐射卫生,2019,28(5):477-479, 484. DOI: 10.13491/j.issn.1004-714X.2019.05.001 Liu LB, Chen Q. Diagnostic analysis of radiational thyroid disease[J]. Chin J Radiol Health, 2019, 28(5): 477-479, 484. DOI: 10.13491/j.issn.1004-714X.2019.05.001 [5] 彭建亮. 131I放射性药物生产工作人员剂量估算与评价[J]. 中国辐射卫生,2019,28(6):662-664. DOI: 10.13491/j.issn.1004-714X.2019.06.017 Peng JL. Dose estimation and evaluation for 131I radioactive pharmaceuticals production workers[J]. Chin J Radiol Health, 2019, 28(6): 662-664. DOI: 10.13491/j.issn.1004-714X.2019.06.017 [6] 高艺莹, 文湘闽, 李红, 等. 某碘[131I]化钠口服溶液生产线辐射安全评价[J]. 职业卫生与病伤,2016,31(3):133-135. DOI: CNKI:SUN:ZYWB.0.2016-03-002 Gao YY, Wen XM, Li H, et al. Safety analysis and evaluation of the radiation protective measures for the production line of a sodium 131I oral solution[J]. J Occup Health Damage, 2016, 31(3): 133-135. DOI: CNKI:SUN:ZYWB.0.2016-03-002 [7] 贾明. 我国除碘技术的研究和应用现状[J]. 辐射防护通讯,1992,12(4):18-23 Jia M. Research and Application of Iodine Removal Technology in China[J]. Radiat Prot Bull, 1992, 12(4): 18-23 [8] 赵超, 唐方东, 何林峰, 等. 气态放射性碘的制备与控制研究[J]. 中国辐射卫生,2015,24(3):290-292. DOI: 10.13491/j.cnki.issn.1004-714X.2015.03.044 Zhao C, Tang FD, He LF, et al. Methods for generation and control of gaseous radioactive iodine[J]. Chin J Radiol Health, 2015, 24(3): 290-292. DOI: 10.13491/j.cnki.issn.1004-714X.2015.03.044 [9] 梁飞, 李永国, 张计荣, 等. 核燃料后处理厂溶解废气中放射性碘吸附材料的研究与应用[J]. 中国辐射卫生,2015,24(4):423-426. DOI: 10.13491/j.cnki.issn.1004-714x.2015.04.039 Liang F, Li YG, Zhang JR, et al. Research and application of adsorbents for removing radioiodine from dissolver off-gas in nuclear fuel reprocessing plant[J]. Chin J Radiol Health, 2015, 24(4): 423-426. DOI: 10.13491/j.cnki.issn.1004-714x.2015.04.039 [10] 王永仙, 武明亮, 安凯媛, 等. 一种用于控制放射性气溶胶的雾化固定技术[J]. 污染防治技术,2013,26(3):52-54, 60. DOI: CNKI:SUN:WRFZ.0.2013-03-019 Wang YX, Wu ML, An KY, et al. A fogging process for fixing radioactive aerosol contamination[J]. Pollut Control Technol, 2013, 26(3): 52-54, 60. DOI: CNKI:SUN:WRFZ.0.2013-03-019 [11] Quintana D M, Rodriguez J B, Cournoyer M E . Glovebox decontamination technology comparison[M]. Los Alamos National Lab, 1999. [12] 武明亮, 张文俊, 唐德仲, 等. 放射性气溶胶雾化捕集固定试验初步研究[J]. 辐射防护,2014,34(2):81-85, 90. DOI: 10.3969/j.issn.1000-8187.2014.02.003 Wu ML, Zhang WJ, Tang DZ, et al. Preliminary study on capturing and encapsulating radioactive aerosol[J]. Radiat Prot, 2014, 34(2): 81-85, 90. DOI: 10.3969/j.issn.1000-8187.2014.02.003
|
|
|
|