Application of low-dose CT in lung cancer screening |
BI Jinling, SHENG Mao, DING Lu, HUANG Yong |
Department of Oncology, Guangde Road, Hefei Second People's Hospital, Hefei 230011 China |
|
|
Abstract Objective To explore the value of pulmonary nodules in low-dose CT and follow-up standard diagnostic CT for lung cancer screening. Methods A total of 21 subjects who have been screened for lung cancer by low-dose CT and follow-up standard diagnostic CT were randomly selected. Both CT image sets for all subjects were independently evaluated by five specialized physicians. Results There were no significant differences between low-dose CT screening and follow-up standard diagnostic CT for lung cancer screening. The concordance rate for the diagnoses of nodule disease was approximately 82% (P<0.001)for all categories. Agreement of the evaluation of all categories in the final diagnosis exceeded 96% (P<0.001). With low-dose CT, the effective dose ranged from 1.5 to 3.6 mSv, whereas in the follow-up diagnostic CT, the effective dose ranged from 8.7 to 15.2 mSv. Conclusion Low-dose CT can be effectively used as an alternativeto standard-dose CT in order to reduce the radiation dose, in the follow-up of pulmonary nodules.
|
Received: 03 March 2018
|
|
|
|
|
[1] Bach PB, Jett JR, Pastorino U, et al. Computed tomography screening andlung cancer outcomes[J]. JAMA, 2007, 297:953-961. [2] Bach PB, Mirkin JN, Oliver TK, et al. Benefits and harms of CT screening forlung cancer:a systematic review[J]. JAMA, 2012, 307:2418-2429. [3] Croswell JM, Baker SG, Marcus PM, et al.cumilative incidence of falsepositivetest results in lung cancer screening. a randomized trial[J]. Ann InternMed, 2010, 152:505-512. [4] Wielpütz MO, Wroblewski J, Lederlin M, et al. Computer-aided detection of artificial pulmonary nodules using an exvivo lung phantom:Influence of exposure parameters and iterative reconstruction[J].Eur J Radiol,2015, 84:1005-1011. [5] Marasinghe JC, Ohkubo M, Kobayashi H, et al.Feasible method to assess the performance of a lung cancer CT screening CADsystem in clinical practice:dependence on nodule size and density[J]. InternationalJournal of Medical Physics, Clinical Engineering and Radiation Oncology, 2014, 3:107-116. [6] okiT, Nakata H, Watanabe H, et al. Evolution of peripheral lungadenocarcinomas:CT findings correlated with histology and tumor doublingtime[J]. AJR Am J Roentgenol, 2000, 174:763-768. [7] Naidich DP, Bankier AA, MacMahon H,et al. Recommendations for the management of subsolid pulmonary nodulesdetected at CT:a statement from the Fleischner Society[J]. Radiology, 2013, 266:304-317. [8] Horeweg N, Scholten ET, de Jong PA, et al. Detection of lung cancer through low-doseCT screening (NELSON):a prespecified analysis of screening test performance andinterval cancers[J]. The Lancet Oncology, 2014, 15:1342-1350. [9] 蒋其兵.螺旋CT常规剂量与低剂量扫描检出肺结节的对比研究[J].中国现代手术学杂志,2013,17(04):313-316. [10] 朱天照,唐光健,蒋学祥.低剂量螺旋CT肺结节扫描与常规剂量CT的对照研究[J].中华放射学杂志,2004(04):92-95. [11] 王凤. 螺旋CT低剂量与常规剂量扫描对肺结节显示率的对比分析[A]//中国中药杂志2015/专集:基层医疗机构从业人员科技论文写作培训会议论文集[C]. 2016:1. [12] 李骞昊,刘翰林.低剂量螺旋CT扫描与常规剂量扫描在肺结节诊断中的对比研究[J].现代医用影像学,2017,26(06):1542-1544. [13] Woolf SH, Harris RP, Campos-Outcalt D. Low-dose computed tomography screening forlung cancer:how strong is the evidence[J].JAMA Intern Med, 2014, 174:2019-2022. [14] Patz EF, Pinsky P, Gatsonis C,et al. Overdiagnosis in low-dose computedtomography screening for lung cancer[J]. JAMA Intern Med, 2014, 174:269-274. [15] Gould MK. Clinical practice.Lung-cancer screening with low-dose computedtomography[J]. The New England journal of medicine, 2014, 371(19):1813-1820. [16] 蒋颖,蒋岳,高红.多层螺旋CT低剂量扫描诊断肺结节的价值[J].中国医学影像学杂志,2007(05):373-374. [17] 郭剑波,李玉林.常规剂量与低剂量CT扫描诊断在肺结节中的价值探讨[J].中国现代药物应用,2017,11(11):7-9. [18] 魏东勇.常规剂量和低剂量CT扫描对肺结节的诊断结果对比分析[J].河南外科学杂志,2016,22(04):134-135. [19] 陈丽.常规剂量CT扫描和低剂量CT扫描诊断肺结节的诊断结果研究[J].影像研究与医学应用,2018,2(05):46-47. |
|
|
|