Protective effect on subjects receiving lung CT scan |
CHEN Shuyang, SHAYA· Nazihan, WANG Ziheng, ZHAO Jinwen, ZHOU Xu, YANG Xiangshan |
School of Public Health, Jilin University, Changchun 130021 China |
|
|
Abstract Objective To determine the radiation dose of sensitive organs under different protective methods in lung CT scanning environment, and to explore the best protective scheme of corresponding organs. Methods Annealed thermoluminescence dose elements were placed in the stomach, liver, colon, and thyroid gland of a simulated human body model. The dose effect experiment of protective methods included non-protective group, half lead apron group, and full lead apron group. The dose effect experiment of protective thickness included 0.50 mmpb full lead apron group and 0.35 mmpb full lead apron group. The same exposure conditions of lung CT scan were used in the above experiments. Results Compared with the non-protective group, the exposure dose of the stomach, liver, colon, and thyroid gland increased significantly in the half lead apron group (P < 0.05), and the exposure dose of the thyroid gland and colon decreased significantly in the full lead apron group (P < 0.05). There were no significant differences in the exposure dose of the liver, stomach, and colon in the simulated human body model between the 0.35 mmpb full lead apron group and the 0.50 mmpb full lead apron group.Conclusion For lung CT scan, the protective measure of lead apron may not reduce the exposure dose of subjects. The protective thickness of lead apron does not necessarily have a substantial influence on the exposure dose of human body.
|
Received: 17 February 2022
|
|
|
|
|
[1] 张文康. “九五”期间全国医疗照射水平调查研究专刊[J]. 中华放射医学与防护杂志,2001,20(S1):7 Zhang WK. Special issue of the national survey of medical exposure levels during the ninth Five-Year Plan period[J]. Chin J Radiol Med Prot, 2001, 20(S1): 7 [2] 徐辉, 王建超, 黄卓, 等. 宽束多排螺旋CT剂量的测量研究[J]. 中国辐射卫生,2017,26(6):623-626,636. DOI: 10.13491/j.cnki.issn.1004-714X.2017.06.001 Xu H, Wang JC, Huang Z, et al. Measurement studies on the CTDI of wide-beam multi-slice spiral CT[J]. Chin J Radiol Health, 2017, 26(6): 623-626,636. DOI: 10.13491/j.cnki.issn.1004-714X.2017.06.001 [3] 朱懿恒, 廖云粤. 基于社会效益与经济效益的大型医疗设备成本效益分析[J]. 中国医学装备,2017,14(5):38-40. DOI: 10.3969/J.ISSN.1672-8270.2017.05.010 Zhu YH, Liao YY. A cost benefit analysis of large medical equipment based on the benefits of economy and society[J]. China Med Equip, 2017, 14(5): 38-40. DOI: 10.3969/J.ISSN.1672-8270.2017.05.010 [4] 吕海蓉, 苏林强, 高燕军, 等. 多层螺旋CT低剂量胸部扫描对肺结节的诊断价值[J]. 海南医学,2020,31(6):751-753. DOI: 10.3969/j.issn.1003-6350.2020.06.022 Lv HR, Su LQ, Gao YJ, et al. Diagnostic value of low-dose multislice spiral CT in pulmonary nodules[J]. Hainan Med J, 2020, 31(6): 751-753. DOI: 10.3969/j.issn.1003-6350.2020.06.022 [5] 喻洁, 叶松, 杨想军, 等. 2018—2019年湖北省医疗照射频度及所致集体剂量研究[J]. 公共卫生与预防医学,2021,32(4):59-62. DOI: 10.3969/j.issn.1006-2483.2021.04.013 Yu J, Ye S, Yang XJ, et al. Frequency and collective dose of medical radiation exposure in Hubei Province in 2018-2019[J]. J Pub Health Prev Med, 2021, 32(4): 59-62. DOI: 10.3969/j.issn.1006-2483.2021.04.013 [6] 邢点金, 范晨烨, 刘昊, 等. 儿童CT检查辐射剂量最优化问题初探[J]. 泰山医学院学报,2020,41(1):72-75. DOI: 10.3969/j.issn.1004-7115.2020.01.020 Xing DJ, Fan CY, Liu H, et al. Study on radiation dose optimization in CT examination of children[J]. J Taishan Med College, 2020, 41(1): 72-75. DOI: 10.3969/j.issn.1004-7115.2020.01.020 [7] 张玉珩, 陈英民, 陈睿, 等. 仿真儿童体模头部CT检查剂量及屏蔽防护效果研究[J]. 中国辐射卫生,2020,29(1):21-25. DOI: 10.13491/j.issn.1004-714X.2020.01.005 Zhang YH, Chen YM, Chen R, et al. Head doses and effects of shielding for head CT scan of children phantom model[J]. Chin J Radiol Health, 2020, 29(1): 21-25. DOI: 10.13491/j.issn.1004-714X.2020.01.005 [8] International Commission on Radiological Protection. ICRP Publication 103. The 2007 recommendations of the international commission on radiological protection[R]. Oxford: Pergamon Press, 2007. [9] 张伟军, 曹吉生, 邓君, 等. 国内部分放射防护器材屏蔽性能分析[J]. 中国辐射卫生,2010,19(1):51-52. DOI: 10.13491/j.cnki.issn.1004-714x.2010.01.015 Zhang WJ, Cao JS, Deng J, et al. Analysis of the shielding performance of part of radiation protection equipment and materials in China[J]. Chin J Radiol Health, 2010, 19(1): 51-52. DOI: 10.13491/j.cnki.issn.1004-714x.2010.01.015 [10] 陈雪梅, 姜晓勃, 陈富强, 等. 铅围脖在乳腺癌术后放疗中对甲状腺的保护作用[J]. 中国辐射卫生,2022,31(1):1-5,12. DOI: 10.13491/j.issn.1004-714X.2022.01.001 Chen XM, Jiang XB, Chen FQ, et al. Protective effects of lead collars on the thyroid in radiotherapy after breast cancer surgery[J]. Chin J Radiol Health, 2022, 31(1): 1-5,12. DOI: 10.13491/j.issn.1004-714X.2022.01.001 [11] 陈伟伟. CT检查中甲状腺、性腺的防护与评价[D]. 济南: 山东省医学科学院, 2008. Chen WW. Protection and evaluation of thyroid gland and gonad in CT examination[D]. Ji’nan: Shandong Academy of Medical Sciences, 2008.
|
|
|
|