|
|
Application on different contrast media concentration in the pancreatic CT angiography scanning |
LI Zhiwei, ZHANG Wanjun |
Department of Radiology, the Second Affiliated Hospital of Soochow University, Suzhou 215004 China |
|
|
Abstract Objective To compare the effects of the different contrast media concentration on the visualization of pancreatic arteries using 64-Detector Spiral CT.Methods 120 cases who underwent abdominal enhancement CT scanning were randomly divided into group A (n = 60) and B (n = 60). The contrast media concentration was 300 mgI/ml for group A and 370 mgI/ml for group B respectively, both groups shared the same contrast media dose algorithm and injection speed, with 0.5 gI/kg body weight and 4 ml/s respectively. Reformating the pancreatic arteries via MIP (maximum intensity projection), VR (volume rendering) and MPR (multi-planar reconstruction).Results The CT value of the abdominal aortic celiac opening of group B is significantly higher than A (P < 0.01). The visualization scores of pancreatic arteriesin Group B are significantly higher than A (P < 0.05). The visualization ratios of pancreatic arteriesin Group Bare higher than A, the differences of AIPDA、PIPDA、DPA、TPA、PMA、CPA between the 2 Groups have statistically significant (P < 0.05).Conclusion Pancreatic arteries could have a better visualization by using 370 mgI/ml contrast media in pancreatic artery scanning.
|
Received: 26 August 2020
|
|
|
|
|
[1] 祖菲, 张晓锦, 史彦杰, 等. 多层螺旋CT血管造影评估糖尿病患者胰腺供血动脉的应用价值[J]. 临床放射学杂志,2017,36(12):1807-1810. DOI: 10.13437/j.cnki.jcr.2017.12.021 Zu F, Zhang XJ, Shi YJ, et al. Multi-slice spiral computed tomography angiography of the feeding arteries of pancreas: comparison with digital subtraction angiography[J]. J Clin Radiol, 2017, 36(12): 1807-1810. DOI: 10.13437/j.cnki.jcr.2017.12.021 [2] Iede K, Nakao A, Oshima K, et al. Early ligation of the dorsal pancreatic artery with a mesenteric approach reduces intraoperative blood loss during pancreatoduodenectomy[J]. J Hepatobiliary Pancreat Sci, 2018, 25(7): 329-334. DOI: 10.1002/jhbp.562 [3] Adamson D, Holzner ML, Wadhera V, et al. Reconstruction of a pancreatic allograft with variant arterial anatomy for transplantation[J]. Transplant Direct, 2019, 5(2): e425. DOI: 10.1097/txd.0000000000000863 [4] Patel BN, Giacomini C, Jeffrey RB, et al. Three-dimensional volume-rendered multidetector CT imaging of the posterior inferior pancreaticoduodenal artery: its anatomy and role in diagnosing extrapancreatic perineural invasion[J]. Cancer Imaging, 2013, 13(4): 580-590. DOI: 10.1102/1470-7330.2013.0051 [5] 李卉, 曾蒙苏, 周康荣, 等. 多层螺旋CT胰腺检查: 多期增强扫描的最佳延迟时间研究[J]. 中华放射学杂志,2004,38(3):287-290. DOI: 10.3760/j.issn:1005-1201.2004.03.014 Li H, Zeng MS, Zhou KR, et al. Multislice spiral CT in pancreas examination: optimal multi-phase enhanced scan delay time[J]. Chin J Radiol, 2004, 38(3): 287-290. DOI: 10.3760/j.issn:1005-1201.2004.03.014 [6] Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches[J]. Radiology, 2010, 256(1): 32-61. DOI: 10.1148/radiol.10090908 [7] Okahara M, Mori H, Kiyosue H, et al. Arterial supply to the pancreas; variations and cross-sectional anatomy[J]. Abdom Imaging, 2010, 35(2): 134-142. DOI: 10.1007/s00261-009-9581-0 [8] 张云轩, 张鹤, 信亚周, 等. 螺旋CT低剂量扫描对肺结核病情监测的应用价值[J]. 中国辐射卫生,2019,28(1):95-97. DOI: 10.13491/j.issn.1004-714x.2019.01.026 Zhang YX, Zhang H, Xin YZ, et al. Application value of spiral CT low-dose scanning in monitoring the condition of pulmonary tuberculosis[J]. Chin J Radiol Heal, 2019, 28(1): 95-97. DOI: 10.13491/j.issn.1004-714x.2019.01.026 [9] Lee SL, Ku YM, Choi BG, et al. Multidetector-row computed tomography (MDCT) findings of adnexal torsion: an analysis of 116 patients[J]. Diagn Interv Imaging, 2016, 97(9): 899-905. DOI: 10.1016/j.diii.2016.03.004 [10] 信亚周, 张云轩. 螺旋CT低剂量扫描在肺部疾病诊断中的应用进展[J]. 中国辐射卫生,2019,28(1):109-112. DOI: 10.13491/j.issn.1004-714x.2019.01.030 Xin YZ, Zhang YX. Progress in the application of spiral CT low-dose scanning in the diagnosis of pulmonary diseases[J]. Chin J Radiol Heal, 2019, 28(1): 109-112. DOI: 10.13491/j.issn.1004-714x.2019.01.030 [11] 朱捷, 周翔平, 刘荣波, 等. 胰腺动脉螺旋CT解剖的研究-正常表现及临床意义[J]. 实用放射学杂志,2005,21(3):260-264. DOI: 10.3969/j.issn.1002-1671.2005.03.010 Zhu J, Zhou XP, Liu RB, et al. Study of pancreatic arterial anatomy with sprial CT scanning: normal appearences and clinical implications[J]. J Pract Radiol, 2005, 21(3): 260-264. DOI: 10.3969/j.issn.1002-1671.2005.03.010 [12] 张庆, 魏兆龙, 李琨, 等. 多排(层)螺旋CT动脉血管CTA扫描及其辐射防护探讨[J]. 中国辐射卫生,2014,23(5):441-443. DOI: 10.13491/j.cnki.issn.1004-714x.2014.05.027 Zhang Q, Wei ZL, Li K, et al. The discussion of Multi-slice(row) spiral CT angiography (CTA) and its radiation protection[J]. Chin J Radiol Heal, 2014, 23(5): 441-443. DOI: 10.13491/j.cnki.issn.1004-714x.2014.05.027 [13] Fenchel S, Fleiter TR, Aschoff AJ, et al. Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas[J]. Br J Radiol, 2004, 77(922): 821-830. DOI: 10.1259/bjr/19527646 [14] 吴东, 周康荣, 陈祖望. 螺旋CT门静脉造影: 不同注射速率的对比研究[J]. 中华放射学杂志,2000,34(9):637. DOI: 10.3760/j.issn:1005-1201.2000.09.018 Wu D, Zhou KR, Chen ZW. Spiral CT portography: correlation with different injection rate[J]. Chin J Radiol, 2000, 34(9): 637. DOI: 10.3760/j.issn:1005-1201.2000.09.018 [15] 黄萨, 袁庆海, 田新华. 64层CT胰腺直接供血动脉成像研究[J]. 临床放射学杂志,2009,28(12):1643-1646. DOI: CNKI:SUN:LCFS.0.2009-12-024 Huang S, Yuan QH, Tian XH. Reserch on angiography of the direct feeding arteries of pancreas using 64-slice CT[J]. J Clin Radiol, 2009, 28(12): 1643-1646. DOI: CNKI:SUN:LCFS.0.2009-12-024 [16] 傅强, 王璐. 64排螺旋CT低电压、低浓度对比剂在门静脉系统成像中的应用研究[J]. 中国辐射卫生,2017,26(5):596-599. DOI: 10.13491/j.cnki.issn.1004-714x.2017.05.031 Fu Q, Wang L. Study on the application of 64-slice spiral CT contrast agent with low voltage and low concentration in portal vein system imaging[J]. Chin J Radiol Heal, 2017, 26(5): 596-599. DOI: 10.13491/j.cnki.issn.1004-714x.2017.05.031 |
|
|
|