Estimation of radiation dose of workers in dealing with the lock of afterloading source |
YU Hui, LI Ping, ZHANG Shuxu |
Radiotherapy Center, Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095 China |
|
|
Abstract Objective To estimate the radiation dose of workers in dealing with the lock of the afterloading source.Methods Two phantoms were used to simulate the cervical cancer patient and the radiation worker, thermoluminescent dosimeters (TLD) were placed on surfaces of the phantom mimicked the worker in dealing with the lock of source, and the entrance surface doses (ESD) of the four radiosensitive organs (eye lens, thyroid, breast, gonald) were monitored.Results If the source strength was 370 GBq, the ESD of each OAR would be less than 0.12 mGy in whichever handling time and 1.7%~19.8% decrease after dressing the phantom with the radiation protective clothing.Conclusion In the case of source strength 370 GBq and the handling time 35 s, the ESD of therapist is less than 0.12 mGy without wearing the radiation protective clothing, which amount to the ESD of X ray radiographic examination only once.
|
Received: 06 January 2019
|
|
|
|
|
[1] 汤继英,陈萍.宫颈癌三维后装治疗的研究进展[J].现代中西医结合杂志,2015,(23):2617-2620. [2] 郎锦义,王培,吴大可,等.2015年中国大陆放疗基本情况调查研究[J].中华放射肿瘤学杂志,2016,25(6):541-545. [3] 中华人民共和国环境保护部.第18号令放射性同位素与射线装置安全和防护管理办法[S].北京:中国环境出版社,2011. [4] 中华人民共和国国家质量监督检验检疫总局. JJ G773-2013医用γ射线后装近距离治疗辐射源[S].2013. [5] Nucletron B.V. microSelectron-HDR user manual[M]. Nucletron B.V, 2010. [6] Zhang S, Jiang S, Zhang Q, er.al. Reduction in stray radiation dose using a body-shielding device during external radiation therapy[J]. J Appl Clin Med Phys. 2017 Mar;18(2):206-213. [7] International Commission on Radiological Protection. ICRP publication 103. The 2007 Recommendations of the International Commission on Radiological Protection[R]. Oxford:Pergamon Press, 2007. [8] 刘祥铨,吴京颖,洪惠民,等.福州市医用诊断X射线机摄影所致受检者照射剂量研究[J].中国职业医学,2015,42(6):649-652. [9] 高林峰,郑钧正,卓维海,等.上海市2007年X射线诊断的医疗照射剂量水平[J].环境与职业医学,2009,26(6):537-540. [10] 李明芳,贾育新,麦维基,等. 2013年广东省X射线摄影受检者体表入射剂量分析[J].中国职业医学,2016,43(1):93-96. [11] 陈维,李兴斌,王进,等. 江苏省X射线诊断所致受检者入射体表剂量水平调查[J].中国职业医学,2016,43(1):112-114. [12] 夏春潮,蒲进,李磊,等.头部CT扫描受检者敏感器官体表辐射量及防护措施的初步研究[J].四川大学学报(医学版),2016,47(6):945-948. [13] 冯定华,张增,徐正昌,等.螺旋CT扫描的深部剂量研究[J].中国辐射卫生,2004,13(4):254-255. [14] 殷志杰,张显鹏,李祥林,等. 热释光探测器在头部CT检查中监测晶状体器官的辐射剂量[J].中国介入影像与治疗学,2014,11(5):321-323. [15] 赵峰,曾勇明,彭盛坤,等.数字断层融合技术与多层CT胸部扫描病变检出及辐射剂量的体模研究[J].中华放射学杂志,2012,46(4):363-366. [16] 胡逸民.肿瘤放射物理学[M].北京:原子能出版社,1999. |
|
|
|