Analysis of radiation dose for PET/CT nurse at a hospital |
TANG Mengjian, QIN Zhiying, WU Yingyu, XIE Ping |
GuangXi Center for Disease Prevention and Control, Nanning 530028 China |
|
|
Abstract Objective In this study,significant data on radiation protection obtained by recordingthe whole-body and the fingerradiation dose of nurses engaged in injection inthe PET/CT room,to implement some techniquesfor the radiation protection of the nurses. Methods Thethermoluminescence dosimeter (TDL) worn on the left and right fingersof two nurses, placed on the outside and inside of the lead-based shielding vestments of the left chest to measure the radiation dose.The average exposure dose of one injection and the protective effect of lead-based shielding vestment can be calculated by the numbers of injects and the dose of the nurses during the monitoring period. Results The exposed dose of the left fingers of the two nurses was largerthan that of the right finger, and the average dose of one injection was 5.8~13.0μSv,the difference was0.4 to 0.8 times; The dose value ofthe inside of the vestment was less than that the outside, and the radiation attenuation rate of the vestment was between 2.8% and 6.6%. Conclusion For nurses engaged in 18F injection in the PET/CT room, the finger dose mainly depends on the number of injections, the dose of injection drugs and the proficiency in the injection. The protective effect of lead-based shielding vestment is very limited.The nurses can be effectively protected only by improving proficiency in injection operation and shortening the exposure time of 18Fradiation.
|
Received: 15 November 2018
|
|
|
|
|
[1] 练德幸,张庆召,张奇,等.PET-CT受检者周围剂量水平检测与分析[J].中国医学装备,2017,14(07):44-47. [2] 李卫国,杨国仁,李全太,等.PET/CT放射性核素的分装和注射人员受照剂量[J].中国辐射卫生,2012,21(2):181-183. [3] 张显鹏,李炜,于海涛,王振光,柳怡,杨珂,张巍,刘建伟,唐波,王新云,于夕荣,李连波.正电子发射计算机断层扫描仪质量控制检测人员受照剂量分析[J].中国职业医学,2016,43(6):774-776. [4] 国家质量监督检验检疫总局. GB 18871—2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2003. [5] 国家卫生和计划生育委员会.GBZ 207—2016外照射个人剂量系统性能检验规范[S].北京:中国标准出版社,2016. [6] C.Chiesa,V.De Sanctis,F. Crippa,et al. Radiation dose to technicians per nuclear medicine procedure:comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose.[J]. European journal of nuclear medicine,1997,24(11):1380-1389. [7] Devine Catherine E,Mawlawi Osama. Radiation safety with positron emission tomography and computed tomography.[J]. Seminars in Ultrasound, CT and MRI,2010,31(1):39-45. [8] 彭建亮,周晓剑,李雪琴,等.PET/CT职业照射的剂量估算与分析[J].环境与职业医学,2014,31(5):398-399. [9] 宋颖,安晶刚.对两所医院PET核素分装及注射人员个人剂量值的监测比较[J].中国医学装备,2012,9(9):28-30. [10] 张灶钦,耿继武,林岚,等.广东省部分核医学诊疗工作场所辐射水平及人员受照剂量分析[J].中国辐射卫生,2018,27(1):13-17. |
|
|
|