Detection and Analysis of Protective Performance of Medical Electron Linear Accelerator Based on IEC Standard |
WANG Hong-wei1, HAO Ying-nan2, HE Qiang1, LV Zhi-zheng1, WANG Chun-yu1, CHEN Chong1, FENG Wei1, CHEN Da-wei1 |
1. School of Public Health, Jilin University, Changchun 130021 China; 2. Jilin Province Radioactive Environmental Supervistion Station |
|
|
Abstract Objective According to the IEC 60601-2-1 version 3.1, the protective performance of medical electron linear accelerator is comprehensively analyzed and detected, which will provides reference for the future use of this standard to detect similar equipment.Methods We carries on the field trials and testing on a 6MV medical electron linear accelerator radiation hazard protection related test items, and carry on the comparative analysis between our result and the standard request.Results The medical electron linear accelerator equipment and the operation of the safety interlock system testing content were in line with the standard requirements. Relative surface dose was 58.7%. M area on the patient plane X-ray radiation leak maximum rate was 1.34%. The mean value of X, Y measurements at different combinations of diaphragm conditions were 0.21%, 0.26%, respectively. Multi leaf collimator leakage radiation rate maximum was 3.46%. The maximum leakage radiation combination condition of outside the area M for the gantry was 0°, the beam limiting system was 0°, the X-ray radiation leak maximum rate was 0.11%, and average was 0.08%. Outside the patient plane X-ray radiation leak maximum rate was 0.25%, and the maximum value of ambient dose equivalent rate was 0.08μSv/h.Conclusion Protection against incorrect absorbed dose in the treatment volume, stray radiation in the radiation field, radiation in the patient plane outside the radiation field and the radiation safety for patients and others of the medical electron linear accelerator can reach the IEC 60601-2-1 standard protection requirements.
|
Received: 15 September 2016
|
|
|
|
|
[1] 张良安.电子加速器放射治疗的放射防护标准释疑[J].中国卫生标准管理,2012,3(3):47-56. [2] IEC 60601-2-1 Medical electrical equipment-Part 2-1:Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV[S].Ed3.1,2014. [3] 中华人民共和国国家质量监督检验检疫总局.GB 9706.5-2008医用电气设备第2部分:能量为1MeV至50MeV电子加速器安全专用要求[S].北京:中国标准出版社,2008. [4] 王博. GB 9706.5-2008新版标准与GB 9706.5-1992原版标准主要差异解析[J]. 中国医疗器械信息,2012,05:33-35. [5] 林玉峰. 安全防患——医用加速器质量控制的重点[J].中国医疗设备,2011,02:9-11+151. [6] 中华人民共和国卫生部.GBZ 126-2011电子加速器放射治疗放射防护要求[S].北京:中国标准出版社,2011. [7] 刘胜堂,顾熹豪,文万信.光子射野剂量计算参数研究[J].中国医学物理学杂志,2014,31(2):4723-4726+4755. [8] International Atomic Energy Agency,Radiation protection in the design of radiotherapy facilities:Safety reports series 47[R].Vienna:IAEA pubs, 2006. [9] 马永忠,娄云,万玲,等.36台医用加速器装置泄漏辐射水平测量与分析[J].中国职业医学,2011,38(3):220-222. [10] 杨淑慧,卢峰,张琳,等.某15 MV医用电子加速器M区内、外泄露辐射测量与分析[J].中国辐射卫生,2015,24(2):122-125. |
|
|
|