The analysis of the 21 SPECT equipment's performance test results in Guangdong Province |
TAN Zhan, MA Rui, TAN Guangxiang, GUO Weizhen, LIN Haihui |
Guangdong Province Hospital for Occupational Disease Prevention Treatment, Guangzhou 510300 China |
|
|
Abstract Objective To improve the image quality control of SPECT Equipment by analyzing the performance test results of 21 SPECT Equipment.Methods Performance was done on testing on the 21 SPECT Equipment with image analysis software, following the 2007 edition of the NEMA (National Electrical Manufacturers Association) standard and the standards of manufacturers.Results The unqualified items mainly appeared in the intrinsic integral uniformity and the intrinsic spatial differential linearity.Conclusion To effectively guarantee the image quality, higher awareness of quality control process, stronger emphasis on daily control work, and better technical capability are necessary.
|
Received: 23 August 2017
|
|
|
|
|
[1] NEMA.Standards publication NU1-2007:performance measurements of gamma cameras[S].NEMA,2007. [2] 刘辉,安晶刚,宋颖.SPECT设备固有性能测试及结果分析[J].中国医学装备,2012,9(12):17-19. [3] 卢峰,宋钢,李全太,等.9台SPECT设备性能测试及结果分析[J].中国辐射卫生,2013,19(4):417. [4] 宋颖,刘辉.核医学设备单光子发射计算机成像系统性能现状调查[J].中国医学装备,2015,12(10):9-11. [5] 李永钊,林伟,丁志辉.SPECT质量控制管理[J].现代临床医学生物工程学杂志,1999,5(3):174-176. [6] 姚树林,陈英茂,耿建华,等.SPECT质量控制检测系统的设计与实现[J].中国医学装备,2016,13(9):6-10 |
|
|
|