Shielding Calculation of Medical Co-60 Brachytherapy Room |
QI Hong-zhi1, GAO Kai2, SHANG Ge1 |
1. The First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054 China; 2. Friendship Hospital of Yili Kazak Autonomous Prefecture |
|
|
Abstract Objective Using calculation to evaluate the shielding of construction project work of the Co-60 brachytherapy room in the hospital, prevention and control of radiation hazards to protect the health and safety of radiation workers and the public.Methods Calculatiion was done according to the relevant national standards and the basic principles of radiation protection design.Results The gamma ray was used as an overview of the factors affecting the shielding thickness of the Co-60 brachytherapy room so as to determine the shielding formula.Conclusion The shielding of radiation protection facilities in Co-60 brachytherapy room construction project basically meets the hygienic requirements of architectural design.
|
Received: 21 September 2016
|
|
|
|
|
[1] 中华人民共和国卫生部.GBZ/T 220.2-2009建设项目职业病危害放射防护评价规范第2部分:放射治疗装置[S].北京:中国标准出版社,2009. [2] 中华人民共和国国家卫生和计划生育委员会.GBZ/T 201.3-2014放射治疗机房的辐射屏蔽规范第3部分:γ射线源放射治疗机房[S].北京:中国标准出版社,2014. [3] 国家环境保护总局.HJ/T 61-2001辐射环境监测技术规范[S].北京:中国环境科学出版社,2001:9,16. [4] 国家环境保护局.GB/T 14056-93环境地表γ辐射剂量率测定规范[S].北京:中国标准出版社,1993:3-5. [5] 中华人民共和国国家质量监督检验检疫总局.GB 18871-2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2002. [6] International Atomic Energy Agency. Radiation Protection and Safety in Medical Uses of Ionizing Radiation[S].IAEA,2014. [7] 中华人民共和国国家卫生和计划生育委员会.GBZ 121-2002后装γ源近距离治疗卫生防护标准[S]北京:中国标准出版社,2017. |
[1] |
. [J]. , 2017, 26(4): 475-477. |
|
|
|
|