Progress of the Application of Cone Beam Computed Tomography(CBCT) in Medical Practice |
JIANG Qing-huan, WEI Ke-dao, WANG Jian-chao, CHENG Jin-sheng |
National Institute for Radiological Protection, China CDC, Beijing 100088 China |
|
|
Abstract Objective To understand the recent progress of the application of Cone beam computed tomography(CBCT) in medical practice.Methods This article adopts a inductive and analytical method according to CBCT medical application range through literature review.Results This article provides performance comparisons between the CBCT and MDCT scanners and classifications for CBCT in use of medicine and evaluation of dose ranges for patients in the CBCT scanning. Finally, this article gives some problems on radiological protection in CBCT application of our country.Conclusion The use of CBCT spans has a wide range of clinical specialties and a large range for patient dose in our country.Authors provide a suggestion on making national radiological protection action plant in appropriate use of CBCT.
|
Received: 24 November 2016
|
|
|
|
|
[1] International Commission on Radiological Protection Radiological protection in cone beam computed tomography(CBCT)[M].ICRP publication:129.Ann.Oxford:Pergamon press,2015. [2] International Commission on Radiological Protection.Managing patient dose in multi-detector computed tomography(MDCT)[M]. ICRP publication 102. Ann,2007.(国际放射防护委员会第102号出版物,多排探测器计算机X线体层摄影患者剂量控制[M].岳保荣,牛延涛译,尉可道审校,北京:人民军医出版社,2011). [3] Fahrig R, Dixon R, Pagne T, et al. Dose and image quality for a cone-beam C-arm CT system[J]. Med phys, 2006, 33(12):4541-4550. [4] Schulz B, Heidenreich R, Heidenreich M, et al. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) application[J].Eur J Radiol, 2012,81:4138-4140. [5] Paul J,Jacobi V, Farhang M, et al. Radiation dose and image quality of X-ray volume imaging system:cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy[J] Eur Radiol,2013,23:1582-1593. [6] Morin O, Aubry JF, Aubin M, et al. Physical performance and image optimization of megavoltage cone beam CT[J]. Med phys, 2009,36[4]:1421-1432. [7] Amer A, Marchant T, Syses T, et al. Imaging doses from the Elekta Synergy X-ray cone beam CT system[J]. Br J Radial, 2007,80:476-482. [8] Kim S, Yoshizumi TT, Toncheva G, et al. Comparison of radiation doses between cone beam CT and multi defector CT:TLD measurements[J]. Radiat Prot Dosim. 2008,132(3):339-345. [9] Park MS, Lee KM, Lee B, et al. Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery[J]. Radiat Prot Dosim. 2012,148(4):431-438. [10] Hansen SL, Klang AT, Ekestubbe A, et al. Calculating effective dose on a cone-beam computed tomography derice:3D Accuitomo and 3D Accuitomo FPD[J]. Dentomaxillofac Radiol. 2008, 37:72-79. [11] Miracle AC, Mukherji SK. Cone beam CT of the head and neck, part l:physical principles[J]. Am J Neuroradiol, 2009, 30:1088-1095. [12] Oconnell A, Conover DL, Zhang Y, et al. Cone-beam CT for breast imaging:radiation dose, breast coverage and image quality[J]. AJR, 2010, 195:496-509. [13] Emmerd DS, Vesel J, Shao L, et al. Flat panel detector based volume imaging SPECT/CT[J]. SNM, 2009. [14] Gupta R, Cheung AC, Bartling SH, et al. Flat-panel volume CT:fundamental principles, technology and applications[J]. RadioGraphics, 2008, 28:2009-2022. [15] Greschus S, Kiessling F, Lichy MP, et al. Potential applications of flat-panel volumetric CT in morphologic and functional smoll animal imaging[J]. Neoplasia, 2005,7:730-740. [16] Lee SC, Kim HK, chun IK, et al. A flat-panel detector based micro-CT system:performance evaluation for small-animal imaging[J]. phys Med Biol. 2003,48:4173-4185. [17] Alaei P, Ding G, Guan H. Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plans[J]. Med phys, 2010, 37:244-248. [18] Kwok YM, Irani FG, Tay KH, et al. Effective dose estimates for cone beam computed tomography in interventional radiology[J]. Eur Radiol,2013, 23:3197-3204. [19] Kim S, Sopko D, Toncheva G, et al. Radiation dose from 3D rotational X-ray imaging:organ and effective dose with conversion factors[J]. Radiat Prot dosim.2011, 150:50-54. [20] Schafer S, Nithiananthan S, Mirota DJ, et al. Mobile C-arm cone-beam CT for guidance of spine surgery:image quality, radiation dose and integration with interventional guidance[J]. Med phy. 2011, 38:4563-4574. [21] Reichardt B, Sarwar A, Bartling SH, et al. Musculoskeletal applications of flat-panel volume CT[J]. sckeletal Radiol, 2008, 37:1069-1076. |
|
|
|