Assessment of americium retention in bone by measuring 241Am in the skull with a whole-body counter |
WU Mengmeng1, WANG Wei1, LI Xiaodun2, CHEN Ling1 |
1. China Institute of Atomic Energy, Beijing 102413 China; 2. China Research Institute of Radio-protection, Taiyuan 030006 China |
|
|
Abstract Objective To assess the retention of 241Am in the whole-body bone of worker by measuring the retention of 241Am in the skull. Methods A whole-body counter with high-purity germanium detector was used to measure the 59.5 keV full-energy peak count of 241Am in the skull. The efficiency of the measurement was calibrated by the digital skull phantom combined with the geometric model of the detector. The retention of 241Am in the worker’s skull was calculated. Results The proportion of skull dry weight relative to the whole-body bone dry weight was used as the coefficient to calculate the 241Am deposition in the whole-body bone from the measured activity of skull 241Am. Conclusion With the retention of 241Am in the skull and the proportion of skull dry weight, the retention of 241Am in the whole-body bone of the worker was calculated to be about 806 Bq.
|
Received: 21 November 2022
|
|
|
|
|
[1] International Commission on Radiological Protection. Age-dependent doses to members of the public from intake of radionuclides - Part 2 ingestion dose coefficients[R]. [S. l. ]: ICRP, 1993. [2] Gualdrini G, Battisti P, Biagini R, et al. Development and characterisation of a head calibration phantom for in vivo measurements of actinides[J]. Appl Radiat Isotopes, 2000, 53(1/2): 387-393. DOI: 10.1016/S0969-8043(00)00174-3 [3] Zhang BQ, Ma JZ, Liu LY, et al. CNMAN: a Chinese adult male voxel phantom constructed from color photographs of a visible anatomical data set[J]. Radiat Prot Dosim, 2007, 124(2): 130-136. DOI: 10.1093/rpd/ncm184 [4] 国家质量技术监督局. GB/T 5703—1999 用于技术设计的人体测量基础项目[S]. 北京: 中国标准出版社,1999. The State Bureau of Quality and Technical Supervision. GB/T 5703—1999 Basic human body measurements for technological design[S]. Beijing: Standards Press of China, 1999. [5] National Council on Radiation Protection and Measurements. Development of a biokinetic model for radionuclide-contaminated wounds and procedures for their assessment, dosimetry and treatment[R]. [S. l. ]: NCRP, 2006. [6] 王继先, 陈如松. 中国参考人解剖生理和代谢数据[M]. 北京: 原子能出版社, 1998. Wang JX, Chen RS. Data of anatomical physiological and metabolic characteristics for Chinese reference man[M]. Beijing: Atomic Energy Press, 1998.
|
|
|
|