|
|
Response of radioactivity meter in vertical direction of ionization chamber |
SONG Ying, LIU Hui |
Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088 China |
|
|
Abstract Objective To determine the responses of radioactivity meter at different positions in the vertical direction of the ionization chamber by measuring different radioactive sources. Methods The radiation of cesium-137, cobalt-60, and americium-241 nuclides was measured at different positions in the vertical direction of the ionization chamber with commonly used clinical radioactivity meters. The measured values were fitted to obtain three trend lines. The maximum deviation of the measured values was estimated according to the trend line, and the deviation was estimated at different syringe needle heights. Results According to the trend lines, the maximum deviation of the radioactivity meter CRC-55tR in measuring cesium-137, cobalt-60, and americium-241 nuclides was 5.15%, 5.98%, and 6.25% respectively. The radioactivity meter RM-905a was used to measure three nuclides at different syringe needle heights, and the maximum deviations were −4.33%, −9.9%, and −12.65%, respectively. Conclusion The three nuclides showed different change patterns in measurement with CRC-55tR and RM-905a but similar change patterns in measurement with the same radioactivity meter. The values measured with the same radioactivity meter showed significant deviations at different positions in the vertical direction of the ionization chamber. It is recommended to make position correction for commonly used nuclides. Reducing measurement error and improving measurement accuracy of nuclides are of great significance for radiation protection.
|
Received: 25 November 2022
|
|
|
|
|
[1] 中华医学会核医学分会. 2020年全国核医学现状普查结果简报[J]. 中华核医学与分子影像杂志,2020,40(12):747-749. DOI: 10.3760/cma.j.cn321828-20201109-00403 Chinese Society of Nuclear Medicine. A brief report on the results of the national survey of nuclear medicine in 2020[J]. Chin J Nucl Med Mol Imaging, 2020, 40(12): 747-749. DOI: 10.3760/cma.j.cn321828-20201109-00403 [2] 刘丽娜, 刘斌, 黄蕤, 等. 核医学诊疗的辐射防护与安全[J]. 中国医学影像技术,2017,33(12):1888-1892. DOI: 10.13929/j.1003-3289.201707009 Liu LN, Liu B, Huang R, et al. Radiation protection and safety in nuclear medicine[J]. Chin J Med Imaging Technol, 2017, 33(12): 1888-1892. DOI: 10.13929/j.1003-3289.201707009 [3] 郭美玉. 医用活度计质量控制[J]. 计量与测试技术,2010,37(12):43-44. DOI: 10.3969/j.issn.1004-6941.2010.12.023 Guo MY. Quality control method of medical[J]. Metrol Measur Techn, 2010, 37(12): 43-44. DOI: 10.3969/j.issn.1004-6941.2010.12.023 [4] 刘辉, 范振芳, 李璟瑜, 等. 医用放射性活度计性能测试及分析[J]. 中国医学装备,2017,14(3):28-31. DOI: 10.3969/j.issn.1672-8270.2017.03.007 Liu H, Fang ZF, Li JY, et al. The test and analysis for performance of medical radioactivity meter[J]. China Med Equip, 2017, 14(3): 28-31. DOI: 10.3969/j.issn.1672-8270.2017.03.007 [5] Uushona NV, Khotle TJ. Quality assurance of the dose calibrator[J]. Phys Med, 2007, 23(3/4): 136. DOI: 10.1016/j.ejmp.2007.09.033 [6] 王彬生. 放射性活度计测量的误差来源和控制[J]. 临床工程,2010,25(8):85-86. DOI: 10.3969/j.issn.1674-1633.2010.08.032 Wang BS. Error sources and control measures of medical activity meter[J]. Clin Eng, 2010, 25(8): 85-86. DOI: 10.3969/j.issn.1674-1633.2010.08.032 [7] 于得水, 吴永顺, 黄金梅, 等. 放射性活度计测量准确性因素研究[J]. 计量技术,2019,(9):31-33,72. DOI: 10.3969/j.issn.1000-0771.2019.09.09 Yu DS, Wu YS, Huang JM, et al. Study on the factors of measuring accuracy of radioactive activity meter[J]. Metrol Sci Technol, 2019,(9): 31-33,72. DOI: 10.3969/j.issn.1000-0771.2019.09.09 [8] 张远东, 曾卫华, 侯胜利, 等. 4πγ电离室活度计电流检测装置设计[J]. 核电子学与探测技术,2021,41(2):209-213. DOI: 10.3969/j.issn.0258-0934.2021.02.005 Zhang YD, Zeng WH, Hou SL, et al. Design of current detection device for 4πγ ionization chamber activity meter[J]. Nucl Electron Detect Technol, 2021, 41(2): 209-213. DOI: 10.3969/j.issn.0258-0934.2021.02.005 [9] 国家市场监督管理总局. JJG 377—2019 放射性活度计检定规程[S]. 北京: 中国标准出版社, 2020. State Administration for Market Regulation. JJG 377—2019 Radioactivity meters[S]. Beijing: Standards Press of China, 2020. [10] 中华人民共和国国家质量监督检验检疫总局, 中国国家标准化管理委员会. GB/T 10256—2013 放射性活度计[S]. 北京: 中国标准出版社, 2013. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China, Standardization Administration of China. GB/T 10256—2013 Radioactivity meter[S]. Beijing: Standards Press of China, 2013. [11] 刘秀芹, 郭悦, 赵洪山, 等. 放射性药物活度测量和注射方式的研究[J]. 中国医学装备,2017,14(3):101-104. DOI: 10.3969/j.issn.1672-8270.2017.03.028 Liu XQ, Guo Y, Zhao HS, et al. A research on activity detection and injection way of radiopharmaceutical[J]. China Med Equip, 2017, 14(3): 101-104. DOI: 10.3969/j.issn.1672-8270.2017.03.028 [12] 张庆召, 梁婧, 朱卫国, 等. 核医学科诊疗患者行为学及辐射防护认知调查分析[J]. 中国辐射卫生,2020,29(4):345-347. DOI: 10.13491/j.issn.1004-714X.2020.04.006 Zhang QZ, Liang J, Zhu WG, et al. The investigation of the behavior and radiation protection cognition of nuclear medicine patients[J]. Chin J Radiol Health, 2020, 29(4): 345-347. DOI: 10.13491/j.issn.1004-714X.2020.04.006
|
|
|
|