SRIM-based analysis of distribution features of Bragg peak of carbon ion radiotherapy |
LIANG Yulin1, ZENG Jianrong2, WANG Lun1, FU Qingguo1 |
1. Guangxi Medical University Affiliated Tumor Hospital, Nanning 530021 China; 2. Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 China |
|
|
Abstract Objective To analyze the distribution features of the Bragg peak of carbon ion beams in materials using SRIM software, and to explore the use of computed tomography (CT) number to calculate the incident energy of carbon ion beams. Methods SRIM software was used to study the travel of carbon ion beams (100 to 300 MeV/u) in different equivalent materials, and analyze the effects of the incident energy of carbon ion beams and the type and thickness of equivalent materials on the depth of the Bragg peak of carbon ion beams. Origin 2017 was used to analyze the functional relationship between CT number and water-equivalent Bragg peak depth ratio (Di) through data fitting. Results The ratios of the Bragg peak depths in equivalent materials to that in water almost stayed constant with the increase in the incident energy of carbon ion beams. Through the functional relation between CT number and Di, the Bragg peak depth of a carbon ion beam of a given energy in an equivalent material could be converted to the equivalent Bragg peak depth in water. Conclusion With the water-equivalent Bragg peak depth ratio Di and CT number of different volume units of human tissues, the equivalent Bragg peak depth in water required for the Bragg peak to fall in the tumor can be accurately calculated, which can be used to reversely infer the needed incident energy of carbon ion beams.
|
Received: 23 February 2022
|
|
|
|
|
[1] Tinganelli W, Durante M. Carbon ion radiobiology[J]. Cancers, 2020, 12(10): 3022. DOI: 10.3390/cancers12103022 [2] 夏文龙, 胡伟刚, 戴建荣, 等. 粒子治疗技术的进展[J]. 中华放射肿瘤学杂志,2017,26(8):951-955. DOI: 10.3760/cma.j.issn.1004-4221.2017.08.022 Xia WL, Hu WG, Dai JR, et al. Progress in charged particle therapy[J]. Chin J Radiat Oncol, 2017, 26(8): 951-955. DOI: 10.3760/cma.j.issn.1004-4221.2017.08.022 [3] Shiba S, Wakatsuki M, Ohno T, et al. Differences in linear energy transfer affect cell-killing and radiosensitizing effects of spread-out carbon-ion beams[J]. Anticancer Res, 2020, 40(10): 5497-5502. DOI: 10.21873/anticanres.14561 [4] Suit H, DeLaney T, Goldberg S, et al. Proton vs carbon ion beams in the definitive radiation treatment of cancer patients[J]. Radiother Oncol, 2010, 95(1): 3-22. DOI: 10.1016/j.radonc.2010.01.015 [5] Kraft G. Tumor therapy with heavy charged particles[J]. Prog Part Nucl Phys, 2000, 45: S473-S544. DOI: 10.1016/S0146-6410(00)00112-5 [6] Hosseinzadeh V, Ghaffari H, Rezaeyan A, et al. Estimating organ dose in computed tomography using tube current modulation: a Monte Carlo simulation[J]. Int J Radiat Res, 2021, 19(3): 575-581. DOI: 10.52547/ijrr.19.3.575 [7] 田丽霞, 房冰冰, 朱光昊, 等. 质子束治疗中Bragg峰分布特性的SRIM模拟研究[J]. 中国辐射卫生,2021,30(1):91-93,122. DOI: 10.13491/j.issn.1004-714X.2021.01.020 Tian LX, Fang BB, Zhu GH, et al. Simulation on the Bragg peak distribution based on SRIM in proton therapy[J]. Chin J Radiol Health, 2021, 30(1): 91-93,122. DOI: 10.13491/j.issn.1004-714X.2021.01.020 [8] 金潇, 严源, 韩春彩. 高能质子治疗系统辐射环境影响评价关键问题探讨[J]. 中国辐射卫生,2020,29(1):65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 Jin X, Yan Y, Han CC. Discussion on some key issues in radiation environmental impact assessment of high energy proton therapy system[J]. Chin J Radiol Health, 2020, 29(1): 65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 [9] Ziegler JF, Ziegler MD, Biersack JP. SRIM-The stopping and range of ions in matter (2010)[J]. Nucl Instrum Meth Phys Res Sect B, 2010, 268(11/12): 1818-1823. DOI: 10.1016/j.nimb.2010.02.091 [10] Zarkadoula E, Toulemonde M, Weber WJ. Additive effects of electronic and nuclear energy losses in irradiation-induced amorphization of zircon[J]. Appl Phys Lett, 2015, 107(26): 261902. DOI: 10.1063/1.4939110 [11] Grimes DR, Warren DR, Partridge M. An approximate analytical solution of the Bethe equation for charged particles in the radiotherapeutic energy range[J]. Sci Rep, 2017, 7(1): 9781. DOI: 10.1038/s41598-017-10554-0 [12] Bryant JA, Drage NA, Richmond S. CT number definition[J]. Radiat Phys Chem, 2012, 81(4): 358-361. DOI: 10.1016/j.radphyschem.2011.12.026 [13] Farina E, Piersimoni P, Riccardi C, et al. Geant4 simulation for a study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas with the active scanning system at CNAO[J]. J Phys Conf Ser, 2015, 664: 072048. DOI: 10.1088/1742-6596/664/7/072048 [14] Kraan AC. Range verification methods in particle therapy: underlying physics and Monte Carlo modeling[J]. Front Oncol, 2015, 5: 150. DOI: 10.3389/fonc.2015.00150 [15] 赵攀, 宋钢, 林辉, 等. 基于CT值的外轮廓提取方法在精确放疗计划制定中的实现[J]. 中华放射医学与防护杂志,2007,27(5):463-466. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.015 Zhao P, Song G, Lin H, et al. Implementation of outside contour extraction based on CT number in making plan of accurate radiotherapy[J]. Chin J Radiol Med Prot, 2007, 27(5): 463-466. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.015 [16] 车宇航, 孟乾乾, 张小芳, 等. 碳离子束射程快速验证方法的蒙特卡罗模拟研究[J]. 原子核物理评论,2020,37(4):901-907. DOI: 10.11804/NuclPhysRev.37.2019064 Che YH, Meng QQ, Zhang XF, et al. Monte Carlo study on the method of rapid range verification of carbon ion beam[J]. Nucl Phys Rev, 2020, 37(4): 901-907. DOI: 10.11804/NuclPhysRev.37.2019064 [17] Hamad MK. Bragg-curve simulation of carbon-ion beams for particle-therapy applications: a study with the GEANT4 toolkit[J]. Nucl Eng Technol, 2021, 53(8): 2767-2773. DOI: 10.1016/j.net.2021.02.011 [18] Chiriotti S, Conte V, Colautti P, et al. Microdosimetric simulations of carbon ions using the Monte Carlo code FLUKA[J]. Radiat Prot Dosim, 2018, 180(1/4): 187-191. DOI: 10.1093/rpd/ncx201 [19] Biersack JP, Haggmark LG. A Monte Carlo computer program for the transport of energetic ions in amorphous targets[J]. Nucl Instrum Meth, 1980, 174(1/2): 257-269. DOI: 10.1016/0029-554X(80)90440-1
|
|
|
|