Study on the radiation effect of 99Tcm on workers' hands |
CHEN Liangping1, HAN Chuncai1, XU Zhongyang2 |
1. China Institute of Atomic Energy, Beijing 102413 China; 2. Nuclear and Radiation Safety Center |
|
|
Abstract Object This paper discussed annual equivalent dose to hands of workers in the production process of 99Tcm. Method The equivalent dose of hand caused by the production of 99Tcm was estimated with different protective sheath and working time. Result Based on 250 working days in a year, the equivalent dose of hand with the 3 mm lead protective sleeve was about 668.8 msv/a, and the equivalent dose of handwith the 2 mm tungsten alloy protective sleeve was about 392.7 msv/a; based on 100 working days in a year, the equivalent dose of hand with the 3 mm lead protective sleeve was about 267.3 msv/a, and the equivalent dose of hand with the 2 mm tungsten alloy protective sleeve was about 157.1 msv/a. Conclusion The radiation effect of the hand dose in the production of 99Tcm could not be ignored. The working time should be reasonably allocated or the protective effect should be improved to ensure that the annual equivalent dose to workers' hands is lower than the annual dose limit of 500mSv/a for limbs or skin in GB 18871—2002.
|
Received: 16 April 2020
|
|
|
|
|
[1] 郑钧正. 电离辐射医学应用的防护与安全[M]. 北京: 原子能出版社, 2009. [2] 田佳乐, 贾红梅. 99Tcm-放射性药物的现状和展望[J]. 同位素,2018,31(3):143-156 [3] 罗志福, 吴宇轩, 梁积新. 用于医用核素钼-99的制备方法[J]. 同位素,2018,31(3):129-142 [4] 黄伟, 梁积新, 吴宇轩, 等. 我国放射性同位素制备技术的发展[J]. 同位素,2019,32(3):208-217 [5] 张锦明, 杜进. 中国放射性药物制备的现状及展望[J]. 同位素,2019,32(3):178-185 [6] 国家质量监督检验检疫总局. GB 18871—2002电离辐射防护与辐射源安全基本标准[S]. 北京: 中国标准出版社, 2002. [7] Delacroix D, Guerre J P, Leblanc P, et al. Radionuclide and radiation protection data handbook 2002[J]. Radiat Prot Dosim, 2002, 98(1): 1-168 [8] 国际放射防护委员会2007年建议书. 国际放射防护委员会第103号出版物[M]. 北京: 原子能出版社, 2008. [9] 王正, 徐建锋, 蔡玉婷, 等. 中国放射性药物的现状及发展趋势[J]. 中国食品药品监管,2018,174(7):44-49 [10] 王彬, 高林峰, 钱爱君, 等. 核医学科放射工作人员手部剂量监测结果初探[J]. 中国辐射卫生,2017,26(6):633-636 [11] 崔慧玲, 代彩云, 牟庆超, 等. 不同注射法对手部辐射剂量的影响[J]. 中国辐射卫生,2013,22(6):694-695 [12] 彭建亮. 131I放射性药物生产工作人员剂量估算与评价[J]. 中国辐射卫生,2019,28(6):662-664 [13] 唐孟俭, 覃志英, 吴应, 等. 某院PET/CT室护士胸部和手指受照剂量分析[J]. 中国辐射卫生,2019,28(3):290-291
|
|
|
|