Development of a portable device for monitoring thyroid radiation in emergency |
ZHONG Huaqiang1,2, LUO Zhiping1, LIU Senlin1, ZHANG Ruihuan2, WANG Baofu2 |
1. China Institute of Atomic Energy, Beijing 102413 China; 2. Ratection Co. Ltd. |
|
|
Abstract Objective To meet the requirements of emergency preparation and response in case of radiation accidents, it is necessary to monitor the thyroid dose, estimate effective dose of the exposed individuals quickly and determine the contamination levels and nuclide types as soon as possible for corresponding treatment.Methods Based on the Monte Carlo simulation results of the detection efficiencies for different sizes of NaI detectors and considering its portability and mobility,a portable thyroid radiation dosimeter was developed for rapid medical response in nuclear emergency situations. Furthermore, a software was also developed to estimatethe intake and the committed dose equivalent of radioactive iodine.Results The device is steady and reliable.The energy resolution is 7% (662 keV), and the lower detection limit is less than 15 Bq (for 131I).The detection speed reaches no less than 20 persons per hour, and its total weight is 30 kg. It meets the requirements of being portable and can be easily disassembled and assembled.Conclusion The device can be quickly transported to the accident site in the case of emergency, which meets the requirements of the emergency rescue team to carry out the monitoring and evaluation of thyroid dose on site, filling a technical gap.
|
Received: 22 April 2019
|
|
|
|
|
[1] 杨英,付士波,李修义.切尔诺贝利核事故与甲状腺癌[J].中华放射医学会与防护杂质,2007,27(4):413-415. [2] 李雨,闵锐.切尔诺贝利核事故对健康影响的最新报告[J].国际放射医学核医学杂志,2007,31(1):51-54. [3] 付熙明,袁龙.核与辐射卫生应急现场处置技术分析[J].中国辐射卫生,2015,24(3):277-280. [4] 刘阳,郭庐阵,郑国文,等.特种条件下应急辐射监测系统研制[J].中国辐射卫生,2018,27(1):65-68,73. [5] Whiting JS,Lee WP,Mpanias PD,et al.Determination of spatiallydistributed iodine thyroidal activity using coincidence counting[J].Phys Med Biol, 1981,26(5):921-924. [6] 何力华,宋易阳,陈勤,等.甲状腺剂量仪的研制[J].原子能科学技术,2000,34(S1):161-164. [7] 刘长安,张庆,徐翠华.用于核或放射应急的甲状腺剂量估算软件的研制[J].中国辐射卫生,2006,15(4):399-401. [8] Knoll G F. Radiation Detection and Measurement[M]. Fourth Edition.USA:Wiley,2010. [9] 陈伯显,张智.核辐射物理及探测学[M].哈尔滨:哈尔滨工程大学出版社,2011. [10] 谢利平,康明杰.X射线探测器能量沉积性能的MC计算[C]//全国第五届核仪器及其应用学术会议论文集.海口,2005:65-66,68. [11] 邱有恒,应阳君,王敏,等.光子电子能量沉积的快速MC模拟方法[J].核动力工程,2010,31(S2):171-174. [12] 王红波,张庆召,张震,等.核医学科工作人员职业性内照射研究进展[J].中国辐射卫生,2016,25(2):251-254. [13] 潘自强.电离辐射环境监测与评价[M].北京:原子能出版社,2007. |
|
|
|