Analysis on occupational radiation protection status and influencing factors in a tertiary hospital in Shanghai |
JIA Ru, CHEN Biao, GAO Zhiqun, BEI Wen, CHEN Chunhui |
Inspecting Agency, Shanghai Municipal Health Commission, Shanghai 200031 China |
|
|
Abstract Objective To investigate the occupational radiation protection status and influencing factors.Methods A total of 94 interventional radiation workers in a tertiary hospital in Shanghai were enrolled by using a self-administered questionnaire survey, and the survey data included information on workload, the use of personal protective equipment and auxiliary protective equipment, personal dose monitoring, occupational health examination, factors affecting the use of personal protective equipment.Results In 2017, the workload of cardiovascular, tumor and neurological interventional procedures were relatively large. The use rate of lead apron was 100%, followed by lead collar 97%, while the utilization rates of lead protective glasses, lead rubber caps and lead rubber gloves were only 52%, 23%, 10% and 3%, respectively. The usage rate of ceiling-suspension shields, table-suspension shields and mobile lead barriers were 84%,62% and 69%, respectively. The wearing rate of personal dosimeter was 78%, the number of staff wearing personal dosimeters inside and outside the lead clothing accounted for 49%. The rate of regular occupational health examination was 100%. The comprehensive utilization rate of personal protective equipment and auxiliary protective equipment and the wearing rate of personal dosimeter in tumor interventional workers were the highest. Unbalanced configuration of protective equipment and different awareness of protection were the main reasons for the difference in the use rate of personal protective equipment among different interventional radiologists.Conclusion The hospital should strengthen the construction of radiation safety culture, and further popularize the use of lead apron and auxiliary protective equipment.
|
Received: 20 March 2019
|
|
|
|
|
[1] 张杰,郭云飞,黄杰,等.廊坊市放射工作人员医疗照射频度及受照剂量调查分析[J].中国辐射卫生,2018,27(5):472-475. [2] Botwin K P, Freeman E D,Gruber R D,et al.Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections[J]. Pain Physician, 2001, 4(4):343-348. [3] Balter S.Guidelines for personnel radiation monitoring in the cardiac catheterization laboratory[J]. Catheterization and cardiovascular diagnosis, 1993,30(4):277-279. [4] Folkerts K H, Munz A, Jung S. Estimation of radiation exposure and radiation risk to staff of cardiac catheterization laboratories (Germ)[J]. Occupational Health and Industrial Medicine, 1997, 2(37):55. [5] Vañó E,González L,Guibelalde E,etal.Radiation exposure to medical staff in interventional and cardiac radiology[J].BrJRadiol, 1998,71(849):954-960. [6] 刘峰,朱伟寿,李仲修,等.新疆部分医疗机构放射诊疗设备防护设施调查[J].疾病预防控制通报,2016,31(6):80-82. [7] 孙鹤霞,徐耘,李白石,等.宜昌市介入放射诊疗现状及管理模式研究[J].中国辐射卫生,2017,26(1):25-27. [8] 刘祥铨,刘雯,吴京颖,等.DSA介入诊疗建设项目职业病危害放射防护效果评价[J].海峡预防医学杂志,2016,22(6):63-65. [9] 姚杰,郑钧正,高林峰,等.上海市介入放射学应用现状的调查研究[J].辐射防护,2014,34(5):281-287. [10] 陈秀梅,张容,赖敏华,等.三级医院介入放射防护能力及个人防护现状调查[J].介入放射学杂志,2017,26(2):176-179. [11] EURADOS. ORAMED:Optimization of Radiation Protection of Medical Staff[R].Braunschweig:EURADOS, 2012 [12] Durán A,Hian S K,Miller D L,et al.A summary of recommendations for occupational radiation protection in interventional cardiology[J].CathetCardiovascIntervent, 2013,81(3):562-567. [13] Maeder M,Brunner-La Rocca H P,Wolber T,et al.Impact of a lead glass screen on scatter radiation to eyes and hands in interventional cardiologists[J].CathetCardiovascIntervent, 2006,67(1):18-23. [14] Miller D L,Vaó E,Bartal G,et al.Occupational radiation protection in interventional radiology:A joint guideline of the cardiovascular and interventional radiology society of Europe and the society of interventional radiology[J].CardiovascInterventRadiol, 2010,33(2):230-239. [15] 薛茹,陈尔东,鞠金欣.眼晶状体新剂量限值对介入放射工作人员辐射防护的影响[J].中国辐射卫生,2015,24(3):223-226. [16] Sailer A M,Vergoossen L,Paulis L,et al.Personalized feedback on staff dose in fluoroscopy-guided interventions:A new era in radiation dose monitoring[J].CardiovascInterventRadiol, 2017,40(11):1756-1762. [17] Valentin J.Abstract:Avoidance of radiation injuries from medical interventional procedures,ICRP Publication 85[J].Ann ICRP, 2000,30(2):7. [18] Ploussi A,EfstathopoulosE P.Importance of establishing radiation protection culture in Radiology Department[J].World JRadiol, 2016,8(2):142. |
|
|
|