Application of Monte Carlo Efficiency Transfer Method to the Efficiency Virtual Calibration of LaBr3 Detector |
CAO Qin-jian1,2, LIU Li-ye1, XIA San-qiang1, JIN Cheng-he1, XIONG Wan-chun1, XIAO Yun-shi1, ZHAO Yuan1, WEI Xiao-feng1 |
1. China Institute for Atomic Energy, Beijing 102413 China; 2. China Institute for Radiation Protection |
|
|
Abstract Objective The method of Monte Carlo efficiency transfer was applied to determine full energy peak efficiency of the LaBr3 detector.Methods The method of Monte Carlo efficiency transfer was introduced, and the efficiency transfer factors of the LaBr3 detector were calculated based on the point-source experiments. At last, the results of calculated full energy peak efficiency were compared with the measured values.Results The comparisons between calculations and point source experiments showed that the relative deviations were mostly within ±5% in the energy range of 121.8~1332.5 keV.Conclusion The results showed that the mothed of virtual calibration was more feasible with Monte Carlo efficiency transfer.
|
Received: 02 April 2016
|
|
|
|
|
[1] 付杰,徐翠华.无源效率刻度技术研究进展及应用概况[J].核电子学与探测技术,2007,27(4):799-804. [2] R Venkataraman, F Bronson, V Atrashkevich, et al. Improved detector response characterization method in ISOCS and LabSOCS[R]. Methods and Applications of Radioanalytical Chemistry Conference, 2003, Hawaii, USA. [3] 卫晓峰,刘立业,肖运实,等.蒙特卡罗方法计算高纯锗探测器的全能峰效率[J].辐射防护,2013,33(3):158-163. [4] 张斌全,马吉增,程建平,等.蒙特卡罗方法计算用于低能光子测量的高纯锗探测器效率[J].核电子学与探测技术,2005,25(3):274-277. [5] Moens L, De Donder J, Xi-lei L, et al. Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries[J]. Nuclear Instruments and Methods in Physics Research, 1981, 187:451-472. [6] M.C Lepy et al. Intercomparison of efficiency transfer software for gamma-ray spectrometry[J]. Applied Radiation and Isotopes, 2011, 55:493-503. [7] Radu D, Stanga D, Sima O. ETNA software used for efficiency transfer from a point source to other geometries[J]. Applied Radiation and Isotopes, 2009, 67:1686-1690. [8] Sima, O Arnold, D. Transfer of the efficiency calibration of Germanium gamma-ray detectors using the GESPECOR software[J]. Applied Radiation and Isotopes,2002,56:71-75. [9] Tim Vidmar. EFFTRAN-A Monte Carlo efficiency transfer code for gamma-ray spectrometry[J]. Nuclear Instruments and Methods,2005, A550:603-608. [10] Vidmar, et al. 2010. Testing efficiency transfer codes for equivalence[J]. Applied Radiation and Isotopes, 2010, 68:355-359. [11] M Jurado Vargasa, N Cornejo Diaz, D Perez Sanchez. Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method[J]. Applied Radiation and Isotopes, 2003, 58:707-712. [12] Liu Liye, Ma Jizeng, Didier Franckb, et al.c Monte Carlo efficiency transfer method for full energy peak efficiency calibration of three type HPGe detectors: A coaxial N-type, a coaxial P-type and four BEGe[J]. Nuclear Instruments and Methods in Physics Research, 2006, A564:608-613. [13] 刘立业.中国成年男性参考人体素模型及在剂量测量评价中的应用[D].北京:清华大学,2010. [14] 刘立业,马吉增,张斌全,等.辐射探测器无源效率刻度的方法.中国,CN200510112535.9[P].2008-07-02. [15] 曹勤剑,夏三强,刘立业,等.溴化镧探测器的晶体表征与全能峰效率计算[J].辐射防护,2016,36(6):364-367. |
|
|
|