Analyzing the Result of Individual dose of Interventional workers in Wuhan,2009~2016 |
SHI Meng-die1, WANG Hong1, BAI Wen-juan1, MIN Zhi-teng2 |
1. Wuhan Center for Disease Prevention and Control, Wuhan 430015 China; 2. Wuhan Prevention and Treatment Center for Occupational Disease |
|
|
Abstract Objective To analyze the individual monitoring level and the dynamic change of interventional radiation workers for 17 medical institutions in Wuhan from 2009 to 2016 and provide a reliable basis for ensuring the health of the intervention person's health and the health administration of the administrative department of public health.Methods The monitoring method of thermoluminescence dosemitry was used based on relevant national laws and regulations and relative standards for evaluation.Results The number of intervention staff in wearing personal dosimeters was increased year. The annual dose equivalent per capita is about 0.97 mSv during 8 years, which showed a downward trend year by year; From high dose the composition ratio, the most in 2009, 27.9% and the least in 2014, 3.52%.Conclusion Interventional personnel dose of radiation workers in Wuhan is low and declining, content the requirements of national occupational exposure limits. The intervention personvel's which meets protection consciousness has gradually improved, but personnel involved in the hand external irradiation dose deserves our attention.
|
Received: 22 May 2017
|
|
|
|
|
[1] ICRP. Avoidance of radiation injuries from medical interventional procedures ICRP Publication85[R].Ann ICRP,2000,30(2):1-67. [2] ICRP. Radiation protection in cardiology. ICRP Publication120[R].Ann ICRP,2013,42(1):1-125. [3] NCRP Radiation dose management for fluoroseopically guided interventional medical procedures. NCRP Report NO.168[R].Bethesda, MD:National Council on Radiation and Measurements,2010. [4] 中华人民共和国国家卫生和计划生育委员会.GBZ 128-2016职业性外照射个人监测规范[S].北京:中国标准出版社,2016. [5] 中华人民共和国国家卫生和计划生育委员会.GBZ 207-2016外照射个人剂量系统性能检验规范[S].北京:中国标准出版社,2016. [6] 中华人民共和国国家质量监督检验检疫总局.GB 18871-2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2003. [7] 石梦蝶,王虹,沈勇君,等.武汉市2011-2014年参加全国个人剂量监测比对结果与分析[J].中国辐射卫生,2015,24(6):606-607. [8] 沈勇君,王虹,白文娟,等.某医院2009-2010年介入工作人员个人剂量监测与分析[J].中国辐射卫生,2012,21(3):280-281. [9] 牛菲,闵楠,陈英民,等.2012-2015年山东省介入放射工作人员个人剂量监测结果分析[J].中国辐射卫生,2016,25(6):663-666. [10] 娄云,马永忠,万玲,等.北京市放射性职业人员受外照射个人剂量8年监测结果分析[J].工业卫生与职业病,2010,36(5):300-304. [11] 李鸿成,夏瑞,卢桂才,等.2013年宁夏地区放射工作人员个人剂量监测结果分析[J].宁夏医科大学学报,2015,37(10):1193-1194. [12] 许潇,卢丽丽,王成国,等.2004-2014年内蒙古地区部分放射工作人员个人剂量监测分析[J].中华放射医学与防护杂志,2016,36(2):138-142. [13] 白文娟,聂绍发.2006-2015年武汉市某医院放射工作人员个人剂量监测分析[J].公共卫生与预防医学,2017,28(1):103-106. |
|
|
|