Application frequency and distribution of X-ray diagnostic in Urumqi in 2016 |
LIU Feng1, SUN Xiaona1, ZHANG Yong2, WANG Yuwen1 |
1. Xinjiang Centers for Diseases Prevention Control, Urumqi 830011 China;
2. Urumqi Center for Control and Prevention |
|
|
Abstract Objective To understand the allocation of radiological diagnostic equipment and the frequency of medical radiation exposure in the medical institutions in Urumqi, in order to provide the basis for the reasonable application of medical radiation technology.Methods 174 medical X-ray diagnostic institutions in Urumqi were investigated and analyzed by means of general survey.Results The frequency of routine X-ray diagnostic examination in Urumqi was 757.7 person-times per 1 000 population. The frequency of CT examination was 349 person-times per 1 000 population. And others X-ray diagnoses were 65.6 person-times per 1 000 population. Comparing the three different age groups, the majority of breast radiographs were taken in 0~15 years old group, while the frequency of mammography was greater in the group over 40 years of age than in the other two age groups. The frequency of X-ray diagnostic examination in different age groups was significantly higher in the older group than in the younger group. The frequency of female X-ray diagnosis was slightly higher than that of male's. There were significant differences in X-ray diagnosis between the three age groupsof 0~15 year old、15~40 year old and more than 40 year old (χ2=82.6 P<0.05;χ2=134.2 P<0.05;χ2=7.15 P<0.05).Conclusion In X-ray diagnostic examination, the CT examination has become a major means second only to the X-ray photography examination. The frequency of X-ray diagnostic examination varies among different age groups, suggesting that more attention should be paid to the frequency of X-ray exposure in older age groups. Through this survey, the related regulatory authorities should strengthen the supervision and management of radiation protection in medical institutions, to ensure the justification of diagnostic radiology and radio therapy.
|
Received: 11 June 2018
|
|
|
|
|
[1] UNSCEAR. Source and effects of ionizing radiation,Vol.I[M].UNSCEAR 2008 Report.New York:UN,2010.
[2] 新疆维吾尔自治区统计局.新疆统计年鉴-2016[M].北京:中国统计出版社,2016.
[3] 中华人民共和国国家统计局.中国统计年鉴-2016[M].北京:中国统计出版社,2016.
[4] 孙彦玲,卢桂才,李鸿成,等.宁夏地区医疗照射频率水平调查分析[J].中华放射医学与防护杂志,2016,36(10):757-760,779.
[5] 李朝晖,祖庆,张远浩,等.南平市医疗照射频率调查分析[J].中国辐射卫生,2016,25(2):198-200.
[6] 郑钧正,岳保荣,李述唐,等.我国"九五"期间X射线诊断的医疗照射频率水平[J].中华放射医学与防护杂志,2001,20(s1):20-24.
[7] 李卓长,程清宇,林伏靖,等."九五"期间医用诊断X射线照射频度调查[J].中国辐射卫生,2000,9(4):244-245.
[8] 汤尧,涂彧.不同文化程度公众对医用X射线诊断防护知识情况调查与分析[J].中国辐射卫生,2011,20(2):168-169.
[9] 高林峰,郑钧正,卓维海,等.上海市"十一五"期间X射线诊断的应用频率及其分布研究[J].辐射防护,2014,34(5):274-279.
[10] 徐辉,王建超,黄卓,等.宽束多排螺旋CT剂量的测量研究[J]. 中国辐射卫生, 2017, 26(6):623-625. |
|
|
|