Analysis of occupational exposure dose for some workers in PET/CT radiology departments of Fujian |
CHEN Xindi, QING Yunhua, GUO Jinrui, GUO Huozhong |
Fujian Center for Prevention and Control of Occupational Diseases and Chemical Poisoning, Fuzhou 350025 China |
|
|
Abstract Objective Analysis and evaluation of occupational exposure dose for workers in PET/CT radiology departments of Fujian.Methods According to the monitoring results of ambient dose equivalent rate and personal dose equivalent of radiation works around 5 PET/CT workplaces in Fujian from 2014 to 2016, The occupational exposure doses of PET/CT radiation workers were analyzed and compared with the national standard dose limit.Results The average annual individual effective dose of radiation workers was 0.50 mSv, and the annual effective dose of all radiation workers was less than 5 mSv. Without personal protection measures, the estimated annual maximum radiation doses for hand, head, neck and chest positions of radiation workers engaged in radiopharmaceuticals, injection and PET/CT co-room positioning were 549.0, 137.4 and 134.0 mSv, respectively.Conclusion Under the normal working conditions, the occupational exposure dose of radiation workers is at a low level, which meets the relevant requirements. Without effective personal protective measures, the occupational exposure dose of radiation workers will exceed the national standard on occupational exposure limit.
|
Received: 26 May 2018
|
|
|
|
|
[1] 李卫国,李全太,李海亮.PET/CT放射防护分析及防护现状[J].中国辐射卫生,2011,20(4):511-512.
[2] 苏金明,傅荣华,周建斌,等.统计软件SPSS for Windows实用指南[M].北京:电子工业出版社,2000:361-367.
[3] 国家质量监督检验检疫总局. GB 18871-2002电离辐射防护与放射源安全基本标准[S].北京:中国标准出版社,2002.
[4] 杜钟庆,张继勉.PET/CT工作人员的外照射个人剂量监测[J].工业卫生与职业病, 2017,43(2):158-159.
[5] 邓群,王拓,范胜男,等.2015年我国医用放射工作人员职业外照射个人剂量水平与分析[J].中国辐射卫生,2017,26(4):398-400. |
|
|
|