Discussion on shielding calculation method for proton therapy room
ZHANG Deqin, PAN Yang, LAI Jichuan, CHEN Jiaojiao, LIU Lantao
Beijing Institute of Occupational Disease Prevention and Treatment (The Beijing Prevention and Treatment Hospital of Occupational Diseases for Chemical Industry), Beijing 100093 China
[1] Zhang Z, Hou CS, Lian DX, et al. Study on the shielding and dose rate distributions of therapeutic proton synchrotron accelerator based on Fluka[J]. Radiat Prot Dosimetry, 2017, 178(1): 1-7. DOI: 10.1093/rpd/ncx068 [2] 刘玉连, 赵徵鑫, 张文艺, 等. 质子放射治疗的现状与展望[J]. 中国医学装备,2017,14(7):139-143. DOI: 10.3969/J.ISSN.1672-8270.2017.07.036 Liu YL, Zhao ZX, Zhang WY, et al. The current situation and prospect of proton radiotherapy[J]. China Med Equip, 2017, 14(7): 139-143. DOI: 10.3969/J.ISSN.1672-8270.2017.07.036 [3] 赵木, 常晟, 尚自强. 质子治疗相关设备技术特点分析[J]. 医疗卫生装备,2019,40(3):81-84. DOI: 10.19745/j.1003-8868.2019073 Zhao M, Chang S, Shang ZQ. Technical analysis of proton therapeutic equipment[J]. Chin Med Equip J, 2019, 40(3): 81-84. DOI: 10.19745/j.1003-8868.2019073 [4] 练德幸, 张震, 张庆召, 等. 蒙特卡罗方法在质子重离子加速器治疗场所屏蔽计算中的应用[J]. 中华放射医学与防护杂志,2016,36(8):634-638. DOI: 10.3760/cma.j.issn.0254-5098.2016.08.016 Lian DX, Zhang Z, Zhang QZ, et al. Monte Carlo method for proton and heavy ion treatment room shielding calculation[J]. Chin J Radiol Med Prot, 2016, 36(8): 634-638. DOI: 10.3760/cma.j.issn.0254-5098.2016.08.016 [5] 邹剑明, 许志强, 耿继武, 等. 基于蒙特卡罗方法的质子治疗室屏蔽防护探讨[J]. 中国辐射卫生,2019,28(4):443-446. DOI: 10.13491/j.issn.1004-714X.2019.04.026 Zou JM, Xu ZQ, Geng JW, et al. Radiation shielding design of proton therapy treatment room based on the Monte Carlo method[J]. Chin J Radiol Health, 2019, 28(4): 443-446. DOI: 10.13491/j.issn.1004-714X.2019.04.026 [6] Sunil C. Analysis of the radiation shielding of the bunker of a 230 MeV proton cyclotron therapy facility; comparison of analytical and Monte Carlo techniques[J]. Appl Radiat Isot, 2016, 110: 205-211. DOI: 10.1016/j.apradiso.2016.01.023 [7] 中华人民共和国国家卫生和计划生育委员会. GBZ/T 201.5—2015 放射治疗机房的辐射屏蔽规范 第5部分: 质子加速器放射治疗机房[S]. 北京: 中国标准出版社, 2016. State health and Family Planning Commission of the People's Republic of China. GBZ/T 201.5—2015 Radiation shielding requirements for radiotherapy room—Part 5: radiotherapy room of proton accelerators[S]. Beijing: Standards Press of China, 2016. [8] 单超, 徐坤, 田源, 等. 质子治疗机房的屏蔽设计方案国内外比较[J]. 中华放射医学与防护杂志,2020,40(12):911-918. DOI: 10.3760/cma.j.issn.0254-5098.2020.12.004 Shan C, Xu K, Tian Y, et al. Shielding design scheme for proton therapy treatment rooms: Comparison between Chinese and international radiation shielding standards for radiotherapy facilities[J]. Chin J Radiol Med Prot, 2020, 40(12): 911-918. DOI: 10.3760/cma.j.issn.0254-5098.2020.12.004 [9] Agosteo S, Magistris M, Mereghetti A, et al. Shielding data for 100-250 MeV proton accelerators: double differential neutron distributions and attenuation in concrete[J]. Nucl Instrum Methods Phys Res Sect B, 2007, 265(2): 581-598. DOI: 10.1016/j.nimb.2007.09.046 [10] Sheu RJ, Lai BL, Lin UT, et al. Source terms and attenuation lengths for estimating shielding requirements or dose analyses of proton therapy accelerators[J]. Health Phys, 2013, 105(2): 128-139. DOI: 10.1097/HP.0b013e31828c36f9 [11] Lai BL, Sheu RJ, Lin UT. Shielding analysis of proton therapy accelerators: a demonstration using Monte Carlo-generated source terms and attenuation lengths[J]. Health Phys, 2015, 108(2): S84-S93. DOI: 10.1097/HP.0000000000000280 [12] 金潇, 严源, 韩春彩. 高能质子治疗系统辐射环境影响评价关键问题探讨[J]. 中国辐射卫生,2020,29(1):65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 Jin X, Yan Y, Han CC. Discussion on some key issues in radiation environmental impact assessment of high energy proton therapy system[J]. Chin J Radiol Health, 2020, 29(1): 65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 [13] 林辉, 宋钢, 赵攀, 等. 蒙特卡罗程序MCNP、EGSnrc、DPM剂量计算比较研究[J]. 中华放射医学与防护杂志,2007,27(5):473-476. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.018 Lin H, Song G, Zhao P, et al. Comparisons between Monte Carlo codes: MCNP, EGSnrc and DPM in radiotherapy dose calculation[J]. Chin J Radiol Med Prot, 2007, 27(5): 473-476. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.018