|
|
Influencing factors of medical exposure frequency for community residents |
CAO Yuli1, SU Yinping2, XU Hui2, SUN Quanfu2, CHENG Jinsheng2 |
1. Department of Gynaecology Obstetrics, People's Hospital of Wucheng County, Dezhou 253300 China; 2. National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, WHO Collaborating Centre on Radiation and Health, Beijing 100088 China |
|
|
Abstract Objective To obtain the medical exposure frequency data of residents through a questionnaire survey on mobile phone networks in the community, and to analyze the main influencing factors. Methods A snowball sampling method was used to expand the sampling from medical staff in a county hospital to the community. The questionnaire included personal information such as occupation category, type of medical insurance, and education level as well as basic radiation-related knowledge and medical exposure type and frequency of respondents received in 2021. A logistic regression model was used to analyze the influencing factors of medical exposure. Results A total of 223 respondents were investigated, and 12.56% of them received radiological diagnosis and radiotherapy in 2021. The proportion of males receiving medical exposure was significantly higher than that of females (19.64% vs 10.18%). The likelihood of the person receiving medical exposure increased considerably with age, with the proportion of residents receiving medical exposure at 20, 30, 40, and 50 years of age being 6.25%, 7.95%, 19.23%, and 33.33%, respectively. Of persons who received medical exposure, 57.14% underwent CT scans. Persons participating in the new rural cooperative medical system were likely less to receive radiological diagnosis and radiotherapy than urban workers and residents (OR = 0.55, CI:0.13-2.23, P > 0.05). Conclusion Questionnaire survey in the community can obtain more information about the medical exposure of residents, and age and type of medical insurance are important factors affecting the frequency of medical exposure.
|
Received: 18 September 2022
|
|
|
|
|
[1] United Nations Scientific Committee on the Effects of Atomic Radiation. Source and effects of ionizing radiation[R]. UNSCEAR 2008 Report to the General Assembly with Scientific Annexe. New York: United Nation, 2010. [2] 梁婧, 张庆召, 朱卫国, 等. 2016年我国X射线诊断频度调查的组织和实施[J]. 中华放射医学与防护杂志,2019,39(5):321-324. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.001 Liang J, Zhang QZ, Zhu WG, et al. Implementation of survey on diagnostic medical X-ray frequency in 2016 in China[J]. Chin J Radiol Med Prot, 2019, 39(5): 321-324. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.001 [3] 苏垠平. 部分地区X射线诊断照射频度调查及CT所致癌症风险的研究[D]. 北京: 中国疾病预防控制中心, 2014. Su YP. Research on the frequency of X-ray diagnostic radiation in some areas and the radiatin cancer risk induced by CT[D]. Beijing: Chinese Center for Disease Control and Prevention,2014. [4] 徐辉, 岳保荣, 尉可道, 等. 我国X射线摄影程序受检者入射体表剂量调查结果与分析[J]. 中华放射医学与防护杂志,2019,39(1):68-72. DOI: 10.3760/cma.j.issn.0254-5098.2019.01.013 Xu H, Yue BR, Wei KD, et al. Investigation and analysis on entrance surface dose of patients in radiography procedures in China[J]. Chin J Radiol Med Prot, 2019, 39(1): 68-72. DOI: 10.3760/cma.j.issn.0254-5098.2019.01.013 [5] 徐辉, 岳保荣, 尉可道, 等. 我国CT扫描检查中受检者剂量调查结果与分析[J]. 中华放射医学与防护杂志,2019,39(3):213-217. DOI: 10.3760/cma.j.issn.0254-5098.2019.03.010 Xu H, Yue BR, Wei KD, et al. Investigation and analysis on the dose of the subjects in CT scanning in China[J]. Chin J Radiol Med Prot, 2019, 39(3): 213-217. DOI: 10.3760/cma.j.issn.0254-5098.2019.03.010 [6] 徐辉, 岳保荣, 尉可道, 等. 我国乳腺X射线摄影受检者乳腺剂量水平调查研究[J]. 中国辐射卫生,2016,25(6):641-644. DOI: 10.13491/j.cnki.issn.1004-714X.2016.06.001 Xu H, Yue BR, Wei KD, et al. Research on glandular dose level of mammography in China[J]. Chin J Radiol Health, 2016, 25(6): 641-644. DOI: 10.13491/j.cnki.issn.1004-714X.2016.06.001 [7] 牛亚婷, 苏垠平, 梁婧, 等. 全国医疗照射频度估算方法研究[J]. 中华放射医学与防护杂志,2019,39(5):325-330. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.002 Niu YT, Su YP, Liang J, et al. Study on estimation of medical exposure frequency in China[J]. Chin J Radiol Med Prot, 2019, 39(5): 325-330. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.002 [8] 胡小素, 雷翠萍, 王颖, 等. 医院患儿家长辐射风险认知及其影响因素的研究[J]. 中国辐射卫生,2017,26(5):580-584. DOI: 10.13491/j.cnki.issn.1004-714X.2017.05.025 Hu XS, Lei CP, Wang Y, et al. The study on the cognition of pparental radiation risk and its influencing factors in hospital children[J]. Chin J Radiol Health, 2017, 26(5): 580-584. DOI: 10.13491/j.cnki.issn.1004-714X.2017.05.025 [9] Stata module for estimating sample size for surveys with a dichotomous outcome variable[EB/OL]. http://www.lindenconsulting.org. [10] 刘乾, 杨淑慧, 宋钢, 等. 山东省医用X射线诊断应用频度调查[J]. 中华放射医学与防护杂志,2019,39(5):363-369. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.008 Liu Q, Yang SH, Song G, et al. Survey on frequency of medical X-ray diagnosis in Shandong province[J]. Chin J Radiol Med Prot, 2019, 39(5): 363-369. DOI: 10.3760/cma.j.issn.0254-5098.2019.05.008 [11] 鲁全. 中国医疗保险管理体制变革研究: 府际关系的视角[J]. 中国行政管理,2022(2):77-82. DOI: 10.19735/j.issn.1006-0863.2022.02.09 Lu Q. Understanding the health insurance management in China from the perspective of inter-governmental relation[J]. Chin Public Adm, 2022(2): 77-82. DOI: 10.19735/j.issn.1006-0863.2022.02.09 [12] 赵予涵, 林燕铭. 北京市医药分开综合改革对门诊CT服务利用情况影响的研究[J]. 中华医院管理杂志,2021,37(5):431-435. DOI: 10.3760/cma.j.cn111325-20201017-02001 Zhao YH, Lin YM. Impacts of the clinics-pharmacy separation reform on outpatient CT utilization in Beijing[J]. Chin J Hosp Adm, 2021, 37(5): 431-435. DOI: 10.3760/cma.j.cn111325-20201017-02001 [13] 周书铎, 马晓晨, 袁蓓蓓, 等. 北京市医药分开综合改革对大型检查设备使用情况的影响研究[J]. 中国卫生经济,2019,38(9):22-26. DOI: 10.7664/CHE20190905 Zhou SD, Ma XC, Yuan BB, et al. Research on the comprehensive reform impact of separation of prescribing and dispensing on the usage of large-scale inspection equipment[J]. Chin Health Econ, 2019, 38(9): 22-26. DOI: 10.7664/CHE20190905 [14] Rehani MM, Yang K, Melick ER, et al. Patients undergoing recurrent CT scans: assessing the magnitude[J]. Eur Radiol, 2020, 30(4): 1828-1836. DOI: 10.1007/s00330-019-06523-y
|
|
|
|