Clinical application of optical surface monitoring system in radiotherapy after radical mastectomy for left breast cancer |
KUANG Bei, LIU Zhongqiang, WANG Hui, WU Zhenming, YE Xiqu, LIN Gengxian |
Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 China |
|
|
Abstract Objective To study the setup error under deep inspiration breath hold (DIBH) guided by optical surface monitoring system (OSMS) and free breathing (FB) FB1 and FB2 (without OSMS guidance, directly set up the body marker line by laser lamp) in radiotherapy after radical mastectomy for left breast cancer, and to provide a basis for individualized clinical target volume-planning target volume (CTV-PTV) expansion for the doctor in charge to delineate the target volume. Methods A total of 36 patients with left breast cancer after radical mastectomy were selected and divided into three groups, in which cone beam computed tomography (CBCT) images were taken in three states: DIBH, FB1, and FB2, respectively. CBCT and CT images were analyzed for registration; the absolute error data of linear displacement in the ventro-dorsal, cranio-caudal, and left-right directions were recorded, and the expanding margin was calculated. Results The translation errors in the ventro-dorsal, cranio-caudal, and left-right directions were (0.06 ± 0.22) cm, (0.05 ± 0.23) cm, and (0.01 ± 0.24) cm in the DIBH group, (0.07 ± 0.21) cm, (0.02 ± 0.23) cm, and (0.02 ± 0.21) cm in the FB1 group, and (0.07 ± 0.24) cm, (0.07 ± 0.34) cm, and (0.25 ± 0.09) cm in the FB2 group. The statistical results of the DIBH group and FB1 group in the ventro-dorsal, RTN, and ROLL directions were significantly different (P < 0.05). The statistical results of the FB1 group and FB2 group in the ventro-dorsal direction were significantly different. The relation of three groups in the value of margin of planning target volume was DIBH < FB1 < FB2 in the ventro-dorsal and cranio-caudal directions and FB1 < DIBH < FB2 in the left-right direction. Conclusion OSMS-guided DIBH radiotherapy in patients with left breast cancer after radical mastectomy can reduce the setup error and provide an important basis for individualized CTV-PTV expansion for the doctor in charge to delineate the target volume.
|
Received: 29 August 2022
|
|
|
|
|
[1] Zagar TM, Cardinale DM, Marks LB. Breast cancer therapy-associated cardiovascular disease[J]. Nat Rev Clin Oncol, 2016, 13(3): 172-184. DOI: 10.1038/nrclinonc.2015.171 [2] Hirose TA, Arimura H, Fukunaga JI, et al. Observer uncertainties of soft tissue-based patient positioning in IGRT[J]. J Appl Clin Med Phys, 2020, 21(2): 73-81. DOI: 10.1002/acm2.12817 [3] Early Breast Cancer Trialists' Collaborative Group (EBCTCG). Adjuvant chemotherapy in oestrogen-receptor-poor breast cancer: patient-level meta-analysis of randomised trials[J]. Lancet, 2008, 371(9606): 29-40. DOI: 10.1016/S0140-6736(08)60069-0 [4] Paszat LF, Mackillop WJ, Groome PA, et al. Mortality from myocardial infarction following postlumpectomy radiotherapy for breast cancer: a population-based study in Ontario, Canada[J]. Int J Radiat Oncol Biol Phys, 1999, 43(4): 755-762. DOI: 10.1016/s0360-3016(98)00412-x [5] Stroom JC, Heijmen BJ. Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report[J]. Radiother Oncol, 2002, 64(1): 76-83. DOI: 10.1016/s0167-8140(02)00140-8 [6] Van Herk M. Errors and margins in radiotherapy[J]. Semin Radiat Oncol, 2004, 14(1): 52-64. DOI: 10.1053/j.semradonc.2003.10.003 [7] 李钰, 高岩, 刘世龙, 等. 宫颈癌患者的膀胱充盈度一致性对放疗摆位误差的影响[J]. 中国辐射卫生,2020,29(3):305-308. DOI: 10.13491/j.issn.1004-714X.2020.03.027 Li Y, Gao Y, Liu SL, et al. Effect of consistency of bladder filling volume on set-up errors in radiotherapy for the patients with cervical cancer[J]. Chin J Radiol Health, 2020, 29(3): 305-308. DOI: 10.13491/j.issn.1004-714X.2020.03.027 [8] 甘晓根, 徐子海, 廖福锡. 应用CTVision图像引导分析胸部肿瘤在放疗中的摆位误差[J]. 中国医疗设备,2012,27(7):157-159. DOI: 10.3969/j.issn.1674-1633.2012.07.058 Gan XG, Xu ZH, Liao FX. Analysis of set-up errors with use of CTVision imaging guided thoracic tumor radiation[J]. China Med Devices, 2012, 27(7): 157-159. DOI: 10.3969/j.issn.1674-1633.2012.07.058 [9] Hoisak JDP, Pawlicki T. The role of optical surface imaging systems in radiation therapy[J]. Semin Radiat Oncol, 2018, 28(3): 185-193. DOI: 10.1016/j.semradonc.2018.02.003 [10] 张光伟, 吴何苟, 刘剑锋, 等. 光学表面监测系统自动摆位功能对乳腺癌放疗患者治疗精度及摆位时间的影响[J]. 中国医学物理学杂志,2021,38(4):411-415. DOI: 10.3969/j.issn.1005-202X.2021.04.003 Zhang GW, Wu HG, Liu JF, et al. Effects of automatic setup function of optical surface monitoring system on treatment accuracy and setup time of breast cancer patients undergoing radiotherapy[J]. Chin J Med Phys, 2021, 38(4): 411-415. DOI: 10.3969/j.issn.1005-202X.2021.04.003 [11] Bartlett FR, Colgan RM, Carr K, et al. The UK HeartSpare study: randomised evaluation of voluntary deep-inspiratory breath-hold in women undergoing breast radiotherapy[J]. Radiother Oncol, 2013, 108(2): 242-247. DOI: 10.1016/j.radonc.2013.04.021 [12] Hamming VC, Visser C, Batin E, et al. Evaluation of a 3D surface imaging system for deep inspiration breath-hold patient positioning and intra-fraction monitoring[J]. Radiat Oncol, 2019, 14(1): 125. DOI: 10.1186/s13014-019-1329-6 [13] Laaksomaa M, Sarudis S, Rossi M, et al. AlignRT® and catalystTM in whole-breast radiotherapy with DIBH: is IGRT still needed?[J]. J Appl Clin Med Phys, 2019, 20(3): 97-104. DOI: 10.1002/acm2.12553 [14] 叶程伟, 周继丹, 商强, 等. 基于光学表面成像与锥形束CT结合的综合引导模式在头颈部肿瘤精确放疗中的研究[J]. 中国辐射卫生,2019,28(3):346-350. DOI: 10.13491/j.issn.1004-714X.2019.03.034 Ye CW, Zhou JD, Shang Q, et al. Comprehensive guidance model based on optical surface imaging combined with cone beam CT in head and neck tumors accurate radiation therapy[J]. Chin J Radiol Health, 2019, 28(3): 346-350. DOI: 10.13491/j.issn.1004-714X.2019.03.034 [15] Boda-Heggemann J, Knopf AC, Simeonova-Chergou A, et al. Deep inspiration breath hold-based radiation therapy: aclinical review[J]. Int J Radiat Oncol BiolPhys, 2016, 94(3): 478-492. DOI: 10.1016/j.ijrobp.2015.11.049 [16] Misra S, Mishra A, Lal P, et al. Cardiac dose reduction using deep inspiratory breath hold (DIBH) in radiation treatment of left sided breast cancer patients with breast conservation surgery and modified radical mastectomy[J]. J Med Imaging Radiat Sci, 2021, 52(1): 57-67. DOI: 10.1016/j.jmir.2020.12.004 [17] Falco M, Masojć B, Macała A, et al. Deep inspiration breath hold reduces the mean heart dose in left breast cancer radiotherapy[J]. Radiol Oncol, 2021, 55(2): 212-220. DOI: 10.2478/raon-2021-0008
|
|
|
|