Analysis of results of national personal dose monitoring ability assessment in China, 2018—2020 |
DONG Qianqian1, JIANG Hongmei1, ZHANG Xinghui1, YE Qianou1, ZHANG Ying2 |
1. Dalian Centers for Disease Prevention and Control, Dalian 116035 China; 2. Dalian Municipal Central Hospital, Dalian 116023 China |
|
|
Abstract Objective To determine the effectiveness of quality control measures in the laboratory by participating in the national personal dose monitoring ability assessment, and to improve personal dose monitoring ability and quality. Methods According to the requirements of the National Personal Dose Monitoring Ability Assessment Program and standards, seven groups of personal dosimeter were prepared and irradiated by accurate radiation source as requested, and the dose was measured by the laboratory participating in the assessment. The data were processed, and the uncertainty of the measurement results was evaluated.Results In 2018, the assessment results Hp (10) dose range was 0.68-4.27 mSv, the single group performance deviation was ?0.01 to ?0.06, and the comprehensive performance deviation was 0.04, and the result was qualified. In 2019, the assessment results Hp (10) dose range was 0.74-8.06 mSv, the single group performance deviation was 0.00 to ?0.08, and the comprehensive performance deviation was 0.04, and the result was qualified. In 2020, the assessment results Hp(10) dose range was 0.83-3.93 mSv, the single group performance deviation was ?0.01 to ?0.10, and the comprehensive performance deviation was 0.06, and the result was excellent. Conclusion The personal dose monitoring system in our laboratory runs smoothly, and the monitoring results are accurate and reliable. The laboratory can issue test reports that meet the requirements of national standards.
|
Received: 06 July 2022
|
|
|
|
|
[1] 雷淑钦, 刘峰, 朱东升, 等. 新疆参加全国个人剂量监测系统能力考核结果分析[J]. 首都公共卫生,2019,13(4):215-217. DOI: 10.16760/j.cnki.sdggws.2019.04.015 Lei SQ, Liu F, Zhu DS, et al. Assessment of the results of Xinjiang’s participation in the national individual dose monitoring system[J]. Cap J Public Health, 2019, 13(4): 215-217. DOI: 10.16760/j.cnki.sdggws.2019.04.015 [2] 罗强, 石圣瑞, 李俊娇, 等. 2008—2015年陕西省部分放射工作人员外照射个人剂量监测结果分析[J]. 中华放射医学与防护杂志,2017,37(6):466-470. DOI: 10.3760/cma.j.issn.0254-5098.2017.06.013 Luo Q, Shi SR, Li JJ, et al. Analysis of monitoring results of individual doses to radiation workers from external exposure in Shaanxi province from 2008 to 2015[J]. Chin J Radiol Med Prot, 2017, 37(6): 466-470. DOI: 10.3760/cma.j.issn.0254-5098.2017.06.013 [3] 赵进沛, 孔雪梅, 顾金成, 等. 华北和华中地区2017年部分驻军医院放射工作人员个人剂量分析[J]. 中国职业医学,2019,46(1):114-116. DOI: 10.11763/j.issn.2095-2619.2019.01.024 Zhao JP, Kong XM, Gu JC, et al. Personal radiation dose analysis on workers in military hospitals in North and Central China, 2017[J]. China Occup Med, 2019, 46(1): 114-116. DOI: 10.11763/j.issn.2095-2619.2019.01.024 [4] 姬绪莉, 魏琼, 沈梅, 等. 宁夏2019参加全国个人剂量监测能力考核结果分析[J]. 中国辐射卫生,2020,29(6):637-639. DOI: 10.13491/j.issn.1004-714X.2020.06.015 Ji XL, Wei Q, Shen M, et al. Analysis on the results of Ningxia's participating in the national personal dose monitoring ability assessment in 2019[J]. Chin J Radiol Health, 2020, 29(6): 637-639. DOI: 10.13491/j.issn.1004-714X.2020.06.015 [5] 张远浩, 王洁琼, 黄招民. 南平市个人剂量监测盲样考核结果分析[J]. 职业卫生与应急救援,2017,35(2):136-137. DOI: 10.16369/j.oher.issn.1007-1326.2017.02.013 Zhang YH, Wang JQ, Huang ZM. Examination of blind samples for personal dose monitoring in Nanping city[J]. Occup Health Emerg Rescue, 2017, 35(2): 136-137. DOI: 10.16369/j.oher.issn.1007-1326.2017.02.013 [6] 国家卫生和计划生育委员会. GBZ 207—2016 外照射个人剂量系统性能检验规范[S]. 北京: 中国标准出版社, 2016. National Health and Family Planning Commission of PRC. GBZ 207—2016 Testing criteria of personnel dosimetry performance for external exposure[S]. Beijing: Standards Press of China, 2016. [7] 陈飞, 郭文, 胡爱英, 等. 2018年全国外照射个人剂量监测能力考核结果与分析[J]. 中国辐射卫生,2020,29(2):178-181. DOI: 10.13491/j.issn.1004-714X.2020.02.020 Chen F, Guo W, Hu AY, et al. Result discussion of the nationwide ability assessment for personal external exposure dose monitoring in 2018[J]. Chin J Radiol Health, 2020, 29(2): 178-181. DOI: 10.13491/j.issn.1004-714X.2020.02.020 [8] 翟贺争, 杜仲庆, 吴香君, 等. 2016—2018年参加全国个人剂量监测能力考核结果分析[J]. 中国辐射卫生,2020,29(1):45-48. DOI: 10.13491/j.issn.1004-714X.2020.01.010 Zhai HZ, Du ZQ, Wu XJ, et al. Comparison and analysis of the intercomparison results of national personal dose monitoring from 2016 to 2018[J]. Chin J Radiol Health, 2020, 29(1): 45-48. DOI: 10.13491/j.issn.1004-714X.2020.01.010 [9] 国家卫生健康委员会. GBZ 128—2019 职业性外照射个人监测规范[S]. 北京: 中国标准出版社, 2019. National Health Commission of the People's Republic of China. GBZ 128—2019 Specifications for individual monitoring of occupational external exposure[S]. Beijing: Standards Press of China, 2019. [10] 中华人民共和国国家质量监督检验检疫总局. GB 18871—2002 电离辐射防护与辐射源安全基本标准[S]. 北京: 中国标准出版社, 2004. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. GB 18871—2002 Basic standards for protection against ionizing radiation and for the safety of radiation sources[S]. Beijing: Standards Press of China, 2004. [11] 王恺怡, 丁艳秋, 胡爱英, 等. 2020年全国外照射个人剂量监测能力考核结果与分析[J]. 中国辐射卫生,2021,30(5):555-559. DOI: 10.13491/j.issn.1004-714X.2021.05.006 Wang KY, Ding YQ, Hu AY, et al. Results and analysis of monitoring ability assessment of external exposure personal dose in 2020[J]. Chin J Radiol Health, 2021, 30(5): 555-559. DOI: 10.13491/j.issn.1004-714X.2021.05.006 [12] 郝述霞, 郭文, 胡爱英, 等. 2016年外照射个人剂量监测能力考核检测报告书写存在问题的分析[J]. 中华放射医学与防护杂志,2017,37(10):786-788. DOI: 10.3760/cma.j.issn.0254-5098.2017.10.012 Hao SX, Guo W, Hu AY, et al. Analysis on the problems existing in the writing of the test reports of external individual dose monitoring in 2016[J]. Chin J Radiol Med Prot, 2017, 37(10): 786-788. DOI: 10.3760/cma.j.issn.0254-5098.2017.10.012
|
|
|
|