|
|
Effects of bolus thickness and use frequency on skin dose in postmastectomy intensity-modulated radiotherapy |
WU Zhe, PANG Ya, MING Zhi, LIU Ke, WANG Dong |
Department of Oncology, Zigong First People’s Hospital, Zigong 643000 China |
|
|
Abstract Objective To investigate the effects of bolus thickness and use frequency on skin dose in postmastectomy intensity-modulated radiotherapy. Methods We retrospectively reviewed 20 cases receiving postmastectomy fixed-field intensity-modulated radiotherapy, to analyze the homogeneity index (HI) and conformity index (CI) of the target volume and the skin dose (Dmax, Dmean, and Dmin) of radiotherapy plans with 0.5 cm-thick bolus or 1 cm-thick bolus alone at a use frequency of 5 F, 10 F, 15 F, 20 F, and 25 F versus a combination of 0.5 cm and 1 cm-thick bolus, and fit the relationship between skin dose and bolus use frequency. Results As the bolus use frequency increased, the skin dose increased, the hot spot of the target volume decreased, and the low-dose volume decreased. The HI of the target volume with the 1 cm bolus was better than that with the 0.5 cm bolus at all use frequencies (P < 0.05), and HI decreased with the increase of bolus use frequency. For both 0.5 cm and 1 cm bolus, the CI of the target volume increased initially and then decreased, reaching the maximum value at a frequency of around 15 F; the CI showed significant differences only at 20 F and 25 F between the two types of bolus (P < 0.05). The skin Dmax and Dmean were significant higher with the 0.5 cm bolus than with the 1 cm bolus (P < 0.05). The equation for the relationship between skin dose (D) and bolus use frequency (F) was D = A×F + B×F2 + C. The Dmax and HI with the combination of 0.5 cm bolus (6 F) plus 1 cm bolus (8 F) fell between those with the 0.5 cm bolus (15 F) and those with the 1 cm bolus (15 F) (P < 0.05). Conclusion In postmastectomy fixed-field intensity-modulated radiotherapy, skin dose can be calculated based on bolus use frequency. Mixed use of bolus may be more suitable than use of 0.5 cm bolus or 1 cm bolus alone.
|
Received: 22 August 2021
|
|
|
|
|
[1] 张文, 施林心, 刘亚洲, 等. 三维适形调强放疗在乳腺癌根治术中的应用[J]. 中国辐射卫生,2019,28(2):190-193. DOI: 10.13491/j.issn.1004-714X.2019.02.021 Zhang W, Shi LX, Liu YZ, et al. Application of three-dimensional conformal intensity modulated radiation therapy in radical mastectomy[J]. Chin J Radiol Health, 2019, 28(2): 190-193. DOI: 10.13491/j.issn.1004-714X.2019.02.021 [2] Vu TT, Pignol JP, Rakovitch E, et al. Variability in radiation oncologists' opinion on the indication of a bolus in post-mastectomy radiotherapy: an international survey[J]. Clin Oncol (R Coll Radiol), 2007, 19(2): 115-119. DOI: 10.1016/j.clon.2006.10.004 [3] 刘婷婷, 刘锐锋, 欧阳水根, 等. 硅胶产生的空腔对乳腺癌根治术后调强放射治疗的剂量学影响[J]. 辐射研究与辐射工艺学报,2020,38(3):39-45. DOI: 10.11889/j.1000-3436.2020.rrj.38.030301 Liu TT, Liu RF, Ouyang SG, et al. Dosimetric effects of bolus-generated air cavities in the breast on intensity-modulated radiation therapy after radical mastectomy[J]. J Radiat Res Radiat Process, 2020, 38(3): 39-45. DOI: 10.11889/j.1000-3436.2020.rrj.38.030301 [4] Andic F, Ors Y, Davutoglu R, et al. Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy[J]. J Exp Clin Cancer Res, 2009, 28: 41. DOI: 10.1186/1756-9966-28-41 [5] White J, Tai A, Arthur D, et al. Breast cancer atlas for radiation therapy planning: consensus definitions. 2018. Available from:https://www.rtog.org/LinkClick.aspx?fileticket=vzJFhPaBipE%3d&tabid=236. [6] Ma CC, Zhang WZ, Lu JY, et al. Dosimetric comparison and evaluation of three radiotherapy techniques for use after modified radical mastectomy for locally advanced left-sided breast cancer[J]. Sci Rep, 2015, 5: 12274. DOI: 10.1038/srep12274 [7] 徐诗磊, 张九堂, 张俊俊, 等. 各向异性解析算法与先进外照射光子剂量算法在肺癌VMAT计划中的剂量学差异[J]. 中国医学物理学杂志,2020,37(6):676-679. DOI: 10.3969/j.issn.1005-202X.2020.06.004 Xu SL, Zhang JT, Zhang JJ, et al. Dosimetric differences between Acuros external beam algorithm and anisotropy analysis algorithm in volumetric modulated arc therapy for lung cancer[J]. Chin J Med Phys, 2020, 37(6): 676-679. DOI: 10.3969/j.issn.1005-202X.2020.06.004 [8] Bahhous K, Zerfaoui M, El Khayati N. Dosimetric effect of Bolus frequency and its thickness in postmastectomy three-dimensional conformal radiotherapy on skin dose for superposition algorithm[J]. Iran J Med Phys, 2019, 16(6): 397-404. DOI: 10.22038/ijmp.2018.33900.1426 [9] 张武哲, 陈志坚, 陈创珍. 左侧乳腺癌根治术后不同组织等效补偿膜放疗的效果分析[J]. 第三军医大学学报,2014,36(9):976-978. DOI: 10.16016/j.1000-5404.2014.09.009 Zhang WZ, Chen ZJ, Chen CZ. Analysis of the effect of radiotherapy with bolus of different tissues after radical mastectomy of left breast cancer[J]. J Third Mil Med Univ, 2014, 36(9): 976-978. DOI: 10.16016/j.1000-5404.2014.09.009 [10] Dahn HM, Boersma LJ, de Ruysscher D, et al. The use of bolus in postmastectomy radiation therapy for breast cancer: a systematic review[J]. Crit Rev Oncol Hematol, 2021, 163: 103391. DOI: 10.1016/j.critrevonc.2021.103391 [11] 孔栋, 魏贤顶, 惠琳, 等. Bolus下空腔对各向异性分析算法计算精度影响[J]. 中国辐射卫生,2021,30(1):94-98. DOI: 10.13491/j.issn.1004-714X.2021.01.021 Kong D, Wei XD, Hui L, et al. Effect of cavity under Bolus to shallow dose calculation precision of anisotropic analytical algorithm[J]. Chin J Radiol Health, 2021, 30(1): 94-98. DOI: 10.13491/j.issn.1004-714X.2021.01.021 [12] Tieu MT, Graham P, Browne L, et al. The effect of adjuvant postmastectomy radiotherapy bolus technique on local recurrence[J]. Int J Radiat Oncol Biol Phys, 2011, 81(3): e165-e171. DOI: 10.1016/j.ijrobp.2011.01.002 [13] 吴伟伟, 张群贵, 吴修洪, 等. 乳腺癌术后不同厚度补偿膜调强放疗剂量学分析[J]. 医疗卫生装备,2016,37(9):91-93,112. DOI: 10.7687/J.ISSN1003-8868.2016.09.091 Wu WW, Zhang QG, Wu XH, et al. Dosimetric analysis of intensity-modulated radiotherapy in postoperative breast-cancer patients with different boluses[J]. Chin Med Equip J, 2016, 37(9): 91-93,112. DOI: 10.7687/J.ISSN1003-8868.2016.09.091 [14] Wong G, Lam E, Bosnic S, et al. Quantitative effect of bolus on skin dose in postmastectomy radiation therapy[J]. J Med Imaging Radiat Sci, 2020, 51(3): 462-469. DOI: 10.1016/j.jmir.2020.06.006 [15] Hsu SH, Roberson PL, Chen Y, et al. Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material[J]. Phys Med Biol, 2008, 53(10): 2593-2606. DOI: 10.1088/0031-9155/53/10/010
|
|
|
|