冯骏超, 张琳, 戴宏, 刘玉龙, 卞华慧, 陈炜博, 王优优, 马娅, 刘伟. 双着丝粒染色体自动分析生物剂量估算影响因素研究[J]. 中国辐射卫生, 2018, 27(4): 289-293.
FENG Junchao, ZHANG Lin, DAI Hong, LIU Yulong, BIAN Huahui, CHEN Weibo, WANG Youyou, MA Ya, LIU Wei. Study on the influence factors of automatic analysis of dicentric chromosomes for biodosimetry. , 2018, 27(4): 289-293.
[1] Philippe Voisin. Standards in biological dosimetry:A requirement to perform an appropriate dose assessment[J]. Mutat Res Genet Toxicol Environ Mutagen. 2015,793:115-22. [2] 戴宏,刘玉龙,冯骏超,等. 双着丝粒染色体自动分析生物生物剂量估算研究[J].中华放射医学与防护杂志,2017,37(3):182-186. [3] Chen DQ, Zhang CY. A simple and convenient method for gaining pure populations of lymphocytes at the first mitotic division in vitro[J]. Mutation Research, 1992,282:227-229. [4] 中华人民共和国卫生部. GB/T 28236-2011染色体畸变估算生物剂量方法[S].北京:中国标准出版社,2011. [5] Deperas J, Szluinska M, Deperas-Kaminska M,et al. CABAS:a freely available PC program for fitting calibration curves in chromosome aberration dosimetry[J]. Radiat Prot Dosimetry,2007,124(2):115-123. [6] Gruel G, Grégoire E, Lecas S, et al. Biological dosimetry by automated dicentric scoring in a simulated emergency[J]. Radiat Res, 2013,179(5):557-569. [7] Vaurijoux A, Gruel G, Pouzoulet F, et al. Strategy for population triage based on dicentric analysis[J]. Radiat Res, 2009, 171(5):541-548. [8] Romm H, Ainsbury E, Barnard S,et al. Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios[J]. Health Phys, 2014,106(6):764-771.