马向捷, 何志坚, 袁继龙, 姜庆寰, 李明生, 魏晓, 杨雨泽, 程金生. 石英玻璃用于放射治疗剂量测量可行性的初步实验分析[J]. 中国辐射卫生, 2023, 32(3): 230-234,239.
MA Xiangjie, HE Zhijian, YUAN Jilong, JIANG Qinghuan, LI Mingsheng, WEI Xiao, YANG Yuze, CHENG Jinsheng. Preliminary experimental analysis of the feasibility of quartz glass for radiotherapy dosimetry. Chinese Journal of Radiological Health, 2023, 32(3): 230-234,239.
[1] 黄鹤桥, 魏明建. 辐射剂量计——石英375℃的热释光(TL)峰[J]. 核技术,2006,29(11):826-829. DOI: 10.3321/j.issn.0253-3219.2006.11.007 Huang HQ, Wei MJ. The 375℃ thermoluminescence (TL) peak of quartz[J]. Nucl Techniq, 2006, 29(11): 826-829. DOI: 10.3321/j.issn.0253-3219.2006.11.007 [2] 戴光复, 苑淑渝, 常贺新, 等. 石英前剂量热释光剂量方法研究[J]. 中国辐射卫生,1996,5(1):50-52. DOI: 10.13491/j.cnki.issn.1004-714X.1996.01.028 Dai GF, Yuan SY, Chang HX, et al. The study on pre-dose thermoluminescence method of quartz[J]. Chin J Radiol Health, 1996, 5(1): 50-52. DOI: 10.13491/j.cnki.issn.1004-714X.1996.01.028 [3] 范亚光, 张良安, 戴光复, 等. 利用前剂量技术进行辐射事故剂量重建的研究[J]. 中国辐射卫生,2003,12(3):134-136. DOI: 10.3969/j.issn.1004-714X.2003.03.002 Fan YG, Zhang LA, Dai GF, et al. The study on radiation accident dose reconstruction with the pre-dose technique[J]. Chin J Radiol Health, 2003, 12(3): 134-136. DOI: 10.3969/j.issn.1004-714X.2003.03.002 [4] Maruyama T, Kumamoto Y, Noda Y. Reassessment of γ doses from the atomic bombs in Hiroshima and Nagasaki[J]. Radiat Res, 1988, 113(1): 1-14. DOI: 10.2307/3577175 [5] Sato H, Takatsuji T, Takada J, et al. Measuring the external exposure dose in the contaminated area near the Chernobyl nuclear power station using the thermoluminescence of quartz in bricks[J]. Health Phys, 2002, 83(2): 227-236. DOI: 10.1097/00004032-200208000-00007 [6] 赵红福, 赵志鹏, 王志强, 等. 参与IAEA/WHO医用加速器剂量输出比对的结果及分析[J]. 中国辐射卫生,2019,28(1):69-71. DOI: 10.13491/j.issn.1004-714X.2019.01.019 Zhao HF, Zhao ZP, Wang ZQ, et al. Results and analysis of participation in the medical accelerator dose output comparison organized by IAEA/WHO[J]. Chin J Radiol Health, 2019, 28(1): 69-71. DOI: 10.13491/j.issn.1004-714X.2019.01.019 [7] 李明生, 姜庆寰, 程金生. 应用Geant4模拟EBT3胶片的能量响应和质子射程测量[J]. 中国辐射卫生,2022,31(6):669-673. DOI: 10.13491/j.issn.1004-714X.2022.06.005 Li MS, Jiang QH, Cheng JS. Energy response and proton range measurement with EBT3 film simulated by geant4[J]. Chin J Radiol Health, 2022, 31(6): 669-673. DOI: 10.13491/j.issn.1004-714X.2022.06.005 [8] 王为, 沈奕晨, 蒋马伟. 探讨热释光在螺旋断层放射治疗系统和直线加速器中剂量标定[J]. 中国医学物理学杂志,2019,36(11):1261-1266. DOI: 10.3969/j.issn.1005-202X.2019.11.004 Wang W, Shen YC, Jiang MW. Dosimeteric calibration of thermoluminescence in helical tomotherapy system and linear accelerator[J]. Chin J Med Phys, 2019, 36(11): 1261-1266. DOI: 10.3969/j.issn.1005-202X.2019.11.004 [9] Oonsiri P, Kingkaew S, Vannavijit C, et al. Investigation of the dosimetric characteristics of radiophotoluminescent glass dosimeter for high-energy photon beams[J]. J Radiat Res Appl Sci, 2019, 12(1): 65-71. DOI: 10.1080/16878507.2019.1594092 [10] Izewska J, Bokulic T, Kazantsev P, et al. 50 Years of the IAEA/WHO postal dose audit programme for radiotherapy: what can we learn from 13756 results?[J]. Acta Oncol, 2020, 59(5): 495-502. DOI: 10.1080/0284186X.2020.1723162 [11] 刘小军, 马文. 高剂量率放射治疗生物学效应研究进展[J]. 中国医学装备,2022,19(12):181-186. DOI: 10.3969/J.ISSN.1672-8270.2022.12.038 Liu XJ, Ma W. The latest research progress on FLASH-RT biological effect[J]. China Med Equip, 2022, 19(12): 181-186. DOI: 10.3969/J.ISSN.1672-8270.2022.12.038 [12] Akhani TB, Kale YD, Gandhi YH. Study of Thermal and optical sensitivity of higher thermo luminescence glow peaks in synthetic quartz material[J]. Int J Innov Res Comput Sci Technol, 2022, 10(2): 568-580. DOI: 10.55524/ijircst.2022.10.2.109 [13] 赵英, 张继红, 马燕, 等. 石英前剂量热释光测量方法研究[J]. 原子能科学技术,2011,45(4):483-486 Zhao Y, Zhang JH, Ma Y, et al. Measurement method of quartz pre-dose thermoluminescence[J]. Atom Energ Sci Technol, 2011, 45(4): 483-486 [14] 张继红, 万俊生, 赵英, 等. 石英前剂量热释光影响因素研究[J]. 核技术,2012,35(4):286-290 Zhang JH, Wan JS, Zhao Y, et al. The influence factors on quartz pre-dose thermoluminescence[J]. Nucl Techniq, 2012, 35(4): 286-290 [15] 林志凯, 隈元芳一. 天然石英热释光剂量学特性及剂量测量方法[J]. 中华放射医学与防护杂志,2003,23(3):195-197. DOI: 10.3760/cma.j.issn.0254-5098.2003.03.022 Lin ZK, Wei YFY. Dosimetric characteristics and dose measurement method of natural quartz thermoluminescence[J]. Chin J Radiol Med Prot, 2003, 23(3): 195-197. DOI: 10.3760/cma.j.issn.0254-5098.2003.03.022 [16] 陈义珍, 崔莹, 张卫东, 等. 量程至MGy的石英剂量计性能研究[J]. 同位素,2022,35(4):317-323. DOI: 10.7538/tws.2021.youxian.066 Chen YZ, Cui Y, Zhang WD, et al. The performance of quartz dosimeter with range to MGy[J]. J Isot, 2022, 35(4): 317-323. DOI: 10.7538/tws.2021.youxian.066