SRIM-based analysis of distribution features of Bragg peak of carbon ion radiotherapy
LIANG Yulin1, ZENG Jianrong2, WANG Lun1, FU Qingguo1
1. Guangxi Medical University Affiliated Tumor Hospital, Nanning 530021 China; 2. Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 China
梁育林, 曾建荣, 汪伦, 付庆国. 基于SRIM分析碳离子治疗中Bragg峰的分布特征[J]. 中国辐射卫生, 2022, 31(6): 735-739,745.
LIANG Yulin, ZENG Jianrong, WANG Lun, FU Qingguo. SRIM-based analysis of distribution features of Bragg peak of carbon ion radiotherapy. Chinese Journal of Radiological Health, 2022, 31(6): 735-739,745.
[1] Tinganelli W, Durante M. Carbon ion radiobiology[J]. Cancers, 2020, 12(10): 3022. DOI: 10.3390/cancers12103022 [2] 夏文龙, 胡伟刚, 戴建荣, 等. 粒子治疗技术的进展[J]. 中华放射肿瘤学杂志,2017,26(8):951-955. DOI: 10.3760/cma.j.issn.1004-4221.2017.08.022 Xia WL, Hu WG, Dai JR, et al. Progress in charged particle therapy[J]. Chin J Radiat Oncol, 2017, 26(8): 951-955. DOI: 10.3760/cma.j.issn.1004-4221.2017.08.022 [3] Shiba S, Wakatsuki M, Ohno T, et al. Differences in linear energy transfer affect cell-killing and radiosensitizing effects of spread-out carbon-ion beams[J]. Anticancer Res, 2020, 40(10): 5497-5502. DOI: 10.21873/anticanres.14561 [4] Suit H, DeLaney T, Goldberg S, et al. Proton vs carbon ion beams in the definitive radiation treatment of cancer patients[J]. Radiother Oncol, 2010, 95(1): 3-22. DOI: 10.1016/j.radonc.2010.01.015 [5] Kraft G. Tumor therapy with heavy charged particles[J]. Prog Part Nucl Phys, 2000, 45: S473-S544. DOI: 10.1016/S0146-6410(00)00112-5 [6] Hosseinzadeh V, Ghaffari H, Rezaeyan A, et al. Estimating organ dose in computed tomography using tube current modulation: a Monte Carlo simulation[J]. Int J Radiat Res, 2021, 19(3): 575-581. DOI: 10.52547/ijrr.19.3.575 [7] 田丽霞, 房冰冰, 朱光昊, 等. 质子束治疗中Bragg峰分布特性的SRIM模拟研究[J]. 中国辐射卫生,2021,30(1):91-93,122. DOI: 10.13491/j.issn.1004-714X.2021.01.020 Tian LX, Fang BB, Zhu GH, et al. Simulation on the Bragg peak distribution based on SRIM in proton therapy[J]. Chin J Radiol Health, 2021, 30(1): 91-93,122. DOI: 10.13491/j.issn.1004-714X.2021.01.020 [8] 金潇, 严源, 韩春彩. 高能质子治疗系统辐射环境影响评价关键问题探讨[J]. 中国辐射卫生,2020,29(1):65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 Jin X, Yan Y, Han CC. Discussion on some key issues in radiation environmental impact assessment of high energy proton therapy system[J]. Chin J Radiol Health, 2020, 29(1): 65-68. DOI: 10.13491/j.issn.1004-714X.2020.01.015 [9] Ziegler JF, Ziegler MD, Biersack JP. SRIM-The stopping and range of ions in matter (2010)[J]. Nucl Instrum Meth Phys Res Sect B, 2010, 268(11/12): 1818-1823. DOI: 10.1016/j.nimb.2010.02.091 [10] Zarkadoula E, Toulemonde M, Weber WJ. Additive effects of electronic and nuclear energy losses in irradiation-induced amorphization of zircon[J]. Appl Phys Lett, 2015, 107(26): 261902. DOI: 10.1063/1.4939110 [11] Grimes DR, Warren DR, Partridge M. An approximate analytical solution of the Bethe equation for charged particles in the radiotherapeutic energy range[J]. Sci Rep, 2017, 7(1): 9781. DOI: 10.1038/s41598-017-10554-0 [12] Bryant JA, Drage NA, Richmond S. CT number definition[J]. Radiat Phys Chem, 2012, 81(4): 358-361. DOI: 10.1016/j.radphyschem.2011.12.026 [13] Farina E, Piersimoni P, Riccardi C, et al. Geant4 simulation for a study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas with the active scanning system at CNAO[J]. J Phys Conf Ser, 2015, 664: 072048. DOI: 10.1088/1742-6596/664/7/072048 [14] Kraan AC. Range verification methods in particle therapy: underlying physics and Monte Carlo modeling[J]. Front Oncol, 2015, 5: 150. DOI: 10.3389/fonc.2015.00150 [15] 赵攀, 宋钢, 林辉, 等. 基于CT值的外轮廓提取方法在精确放疗计划制定中的实现[J]. 中华放射医学与防护杂志,2007,27(5):463-466. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.015 Zhao P, Song G, Lin H, et al. Implementation of outside contour extraction based on CT number in making plan of accurate radiotherapy[J]. Chin J Radiol Med Prot, 2007, 27(5): 463-466. DOI: 10.3760/cma.j.issn.0254-5098.2007.05.015 [16] 车宇航, 孟乾乾, 张小芳, 等. 碳离子束射程快速验证方法的蒙特卡罗模拟研究[J]. 原子核物理评论,2020,37(4):901-907. DOI: 10.11804/NuclPhysRev.37.2019064 Che YH, Meng QQ, Zhang XF, et al. Monte Carlo study on the method of rapid range verification of carbon ion beam[J]. Nucl Phys Rev, 2020, 37(4): 901-907. DOI: 10.11804/NuclPhysRev.37.2019064 [17] Hamad MK. Bragg-curve simulation of carbon-ion beams for particle-therapy applications: a study with the GEANT4 toolkit[J]. Nucl Eng Technol, 2021, 53(8): 2767-2773. DOI: 10.1016/j.net.2021.02.011 [18] Chiriotti S, Conte V, Colautti P, et al. Microdosimetric simulations of carbon ions using the Monte Carlo code FLUKA[J]. Radiat Prot Dosim, 2018, 180(1/4): 187-191. DOI: 10.1093/rpd/ncx201 [19] Biersack JP, Haggmark LG. A Monte Carlo computer program for the transport of energetic ions in amorphous targets[J]. Nucl Instrum Meth, 1980, 174(1/2): 257-269. DOI: 10.1016/0029-554X(80)90440-1