Research progress in estimation and monitoring of individual exposure dose based on mobile phones
WANG Kaiyi, GUO Wen, TUO Fei
Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088 China
王恺怡, 郭文, 拓飞. 基于手机的个人受照剂量估算与监测研究进展[J]. 中国辐射卫生, 2022, 31(1): 93-98,112.
WANG Kaiyi, GUO Wen, TUO Fei. Research progress in estimation and monitoring of individual exposure dose based on mobile phones. , 2022, 31(1): 93-98,112.
[1] 于水, 郭力生. 核恐怖事件与医学应急处理[J]. 中国辐射卫生,2003,12(2):115-117. DOI: 10.13491/j.cnki.issn.1004-714X.2003.02.043 Yu S, Guo LS. Nuclear terrorism and medical emergency response[J]. Chin J Radiol Health, 2003, 12(2): 115-117. DOI: 10.13491/j.cnki.issn.1004-714X.2003.02.043 [2] 王晓涛, 陈栋梁. 我国核技术利用的辐射安全监管现状[J]. 环境与职业医学,2013,30(4):295-297, 302. DOI: 10.13213/j.cnki.jeom.2013.04.011 Wang XT, Chen DL. Radiation safety supervision of nuclear technology utilization in China[J]. J Environ Occup Med, 2013, 30(4): 295-297, 302. DOI: 10.13213/j.cnki.jeom.2013.04.011 [3] 金慧英, 杨龙, 荣曙, 等. 从谣“盐”看福岛核泄漏事故对公众心理的影响及对策[J]. 职业卫生与应急救援,2011,29(3):127-129. DOI: 10.16369/j.oher.issn.1007-1326.2011.03.007 Jin HY, Yang L, Rong S, et al. The impact of the Fukushima nuclear accident on public psychology and countermeasures from the rumors "salt"[J]. Occup Health Emerg Rescue, 2011, 29(3): 127-129. DOI: 10.16369/j.oher.issn.1007-1326.2011.03.007 [4] 李冰, 杨端节, 吴德强. 核与辐射应急照射情况下公众照射的防护[J]. 辐射防护,2017,37(2):81-86. DOI: CNKI:SUN:FSFH.0.2017-02-001 Li B, Yang DJ, Wu DQ. Protection of public exposure in nuclear and radiological emergency exposure situation[J]. Radiat Prot, 2017, 37(2): 81-86. DOI: CNKI:SUN:FSFH.0.2017-02-001 [5] 马得勋, 刘书锋, 曹务锐. 核事故医学救援辐射监测工作的几点思考[J]. 辐射防护通讯,2020,40(1):27-29. DOI: 10.3969/j.issn.1004-6356.2020.01.006 Ma DX, Liu SF, Cao WR. Some thoughts on radiation monitoring of medical rescue in nuclear accidents[J]. Radiat Prot Bull, 2020, 40(1): 27-29. DOI: 10.3969/j.issn.1004-6356.2020.01.006 [6] 南宏杰, 杨忠平, 雷鑫. 核应急行动中的剂量监测[C]//第十六届全国核电子学与核探测技术学术年会. 绵阳, 2012: 442-444. Nan HJ,Yang ZP, Lei X. Dose monitoring in nuclear emergency operations[C]//The 16th National Conference on Nuclear Electronics and Nuclear Detection Technology. Mianyang, 2012: 442-444. [7] 郭勇. 电离辐射事故外照射个人剂量估计[J]. 国外医学(放射医学核医学分册),1996,(4):179-183 Guo Y. Personal dose estimation of external exposure to ionizing radiation accident[J]. Foreign Med Sci Nucl Med, 1996,(4): 179-183 [8] 张良安. 回顾性剂量学方法[J]. 国外医学(放射医学核医学分册),1996,(4):31-36 Zhang LA. Retrospective dosimetry approach[J]. Foreign Med Sci Nucl Med, 1996,(4): 31-36 [9] 张良安. 回顾剂量学方法研究的现状和展望[J]. 中华放射医学与防护杂志,1999,(3):164-167. DOI: 10.3760/cma.j.issn.0254-5098.1999.03.008 Zhang LA. Review the current status and prospects of dosimetry method research[J]. Chin J Radiol Med Prot, 1999,(3): 164-167. DOI: 10.3760/cma.j.issn.0254-5098.1999.03.008 [10] 魏贤, 周文琴. 从两起意外照射看佩戴个人剂量计的重要性[J]. 中国辐射卫生,2001,10(4):240. DOI: 10.3969/j.issn.1004-714X.2001.04.043 Wei X, Zhou WQ. Viewing the importance of wearing personal dosimeters from two accidental exposures[J]. Chin J Radiol Health, 2001, 10(4): 240. DOI: 10.3969/j.issn.1004-714X.2001.04.043 [11] 杨喻棋. 浅析智能手机发展历史及未来趋势[J]. 科技创新导报,2019,16(5):1,3. DOI: 10.16660/j.cnki.1674-098X.2019.05.001 Yang YQ. Analysis of the development history and future trends of smart phones[J]. Sci Technol Innov Her, 2019, 16(5): 1,3. DOI: 10.16660/j.cnki.1674-098X.2019.05.001 [12] 陈锐志, 陈亮. 基于智能手机的室内定位技术的发展现状和挑战[J]. 测绘学报,2017,46(10):1316-1326. DOI: 10.11947/j.AGCS.2017.20170383 Chen RZ, Chen L. Indoor positioning with smartphones: the state-of-the-art and the challenges[J]. Acta Geod et Cartogr Sin, 2017, 46(10): 1316-1326. DOI: 10.11947/j.AGCS.2017.20170383 [13] Inrig EL, Godfrey-Smith DI, Khanna S. Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry[J]. Radiat Meas, 2008, 43(2/3/4/5/6): 726-730. DOI: 10.1016/j.radmeas.2007.11.078 [14] Beerten K, Woda C, Vanhavere F. Thermoluminescence dosimetry of electronic components from personal objects[J]. Radiat Meas, 2009, 44(5/6): 620-625. DOI: 10.1016/j.radmeas.2009.02.003 [15] 吴可, 孙存普, 史元明. 手表玻璃作为核事故剂量的ESR检测材料[J]. 辐射研究与辐射工艺学报,1993,11(1):24-27 Wu K, Sun CP, Shi YM. The watch glass use for esr dosimetric material in nuclear accident[J]. J Radiat Res Radiat Process, 1993, 11(1): 24-27 [16] Bassinet C, Trompier F, Clairand I. Radiation accident dosimetry on glass by TL and EPR spectrometry[J]. Health Phys, 2010, 98(2): 400-405. DOI: 10.1097/01.hp.0000346330.72296.51 [17] Discher M, Woda C. Thermoluminescence of glass display from mobile phones for retrospective and accident dosimetry[J]. Radiat Meas, 2013, 53/54: 12-21. DOI: 10.1016/j.radmeas.2013.04.002 [18] Mrozik A, Marczewska B, Bilski P, et al. Investigation of thermoluminescence properties of mobile phone screen displays as dosimeters for accidental dosimetry[J]. Radiat Phys Chem, 2014, 104: 88-92. DOI: 10.1016/j.radphyschem.2014.01.013 [19] Discher M, Woda C. Thermoluminescence emission spectrometry of glass display in mobile phones and resulting evaluation of the dosimetric properties of a specific type of display glass[J]. Radiat Meas, 2014, 71: 480-484. DOI: 10.1016/j.radmeas.2014.05.001 [20] Discher M, Woda C, Fiedler I. Improvement of dose determination using glass display of mobile phones for accident dosimetry[J]. Radiat Meas, 2013, 56: 240-243. DOI: 10.1016/j.radmeas.2013.01.027 [21] Bassinet C, Pirault N, Baumann M, et al. Radiation accident dosimetry: TL properties of mobile phone screen glass[J]. Radiat Meas, 2014, 71: 461-465. DOI: 10.1016/j.radmeas.2014.03.025 [22] Discher M, Hiller M, Woda C. MCNP simulations of a glass display used in a mobile phone as an accident dosimeter[J]. Radiat Meas, 2015, 75: 21-28. DOI: 10.1016/j.radmeas.2015.02.013 [23] Discher M, Greiter M, Woda C. Photon energy dependence and angular response of glass display used in mobile phones for accident dosimetry[J]. Radiat Meas, 2014, 71: 471-474. DOI: 10.1016/j.radmeas.2014.04.011 [24] Fattibene P, Trompier F, Wieser A, et al. EPR dosimetry intercomparison using smart phone touch screen glass[J]. Radiat Environ Biophys, 2014, 53(2): 311-320. DOI: 10.1007/s00411-014-0533-x [25] Göksu HY. Telephone chip-cards as individual dosemeters[J]. Radiat Meas, 2003, 37(6): 617-620. DOI: 10.1016/S1350-4487(03)00082-9 [26] 孙涛. 基于氧化铝器件的应急剂量评估方法[D]. 北京: 军事科学院, 2019. Sun T. Emergency dose assessment method based on alumina devices[D]. Beijing: Academy of Military Sciences PLA China, 2019. [27] Bassinet C, Trompier F, Clairand I. Radiation accident dosimetry on electronic components by OSL[J]. Health Phys, 2010, 98(2): 440-445. DOI: 10.1097/01.HP.0000346335.56701.93 [28] Bassinet C, Woda C, Bortolin E, et al. Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison[J]. Radiat Meas, 2014, 71: 475-479. DOI: 10.1016/j.radmeas.2014.03.016 [29] Pascu A, Vasiliniuc S, Zeciu-Dolha M, et al. The potential of luminescence signals from electronic components for accident dosimetry[J]. Radiat Meas, 2013, 56: 384-388. DOI: 10.1016/j.radmeas.2013.03.013 [30] Mrozik A, Marczewska B, Bilski P, et al. Investigation of OSL signal of resistors from mobile phones for accidental dosimetry[J]. Radiat Meas, 2014, 71: 466-470. DOI: 10.1016/j.radmeas.2014.05.004 [31] 贾育新, 马卫江, 唐强, 等. 集成电路用于测量事故剂量的探索[J]. 中国职业医学,2008,35(2):142,145. DOI: 10.3969/j.issn.1000-6486.2008.02.020 Jia YX, Ma WJ, Tang Q, et al. Study on measuring accidental dose using IC chips[J]. China Occup Med, 2008, 35(2): 142,145. DOI: 10.3969/j.issn.1000-6486.2008.02.020 [32] Fiedler I, Woda C. Thermoluminescence of chip inductors from mobile phones for retrospective and accident dosimetry[J]. Radiat Meas, 2011, 46(12): 1862-1865. DOI: 10.1016/j.radmeas.2011.05.077.DOI:10.1016/j.radmeas.2011.05.077 [33] Sholom S, McKeever SWS. Emergency OSL/TL dosimetry with integrated circuits from mobile phones[C]//SPIE Optical Engineering + Applications. Proc SPIE 9213, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XVI, San Diego, California, USA. 2014, 9213: 216-225. DOI:10.1117/12.2064302. [34] Sholom S, McKeever SWS. Integrated circuits from mobile phones as possible emergency osl/tl dosimeters[J]. Radiat Prot Dosim, 2016, 170(1/2/3/4): 398-401. DOI: 10.1093/rpd/ncv446 [35] Kandemir A, Toktamış H. Thermoluminescence studies of SIM card chips used in mobile communication providers in Turkey[J]. Radiat Phys Chem, 2018, 149: 84-89. DOI: 10.1016/j.radphyschem.2018.04.002 [36] 周亮. 一种可用于辐射剂量监测的手机: CN202907022U[P]. 2013-04-24. [37] 周亮, 徐君乐. 微型个人辐射剂量探测器: CN205643723U[P]. 2016-10-12. [38] 胡维. 一种可以监测辐射量和辐射距离的智能腕带: CN106683334A[P]. 2017-05-17. [39] 时良辰, 李源, 高志民, 等. 一种基于移动互联网的辐射剂量巡测仪: CN206671573U[P]. 2017-11-24. [40] 李忠. 基于SiPM的个人剂量仪的研制[D]. 兰州: 兰州大学, 2017. Li Z. The development of personal dosimeter based on SiPM[D]. Lanzhou: Lanzhou University, 2017. [41] 季翔, 吴宜灿, 赵柱民, 等. 一种基于手机自身图像传感器的辐射剂量监测系统及监测方法: CN106371126A[P]. 2017-02-01. [42] 左卓, 柳炳琦, 肖婷婷. 一种Android系统的智能手机γ个人剂量仪[J]. 电子世界,2016(11):103-104. DOI: 10.19353/j.cnki.dzsj.2016.11.074 Zuo Z, Liu BQ, Xiao TT. A smart phone gamma personal dosimeter for Android system[J]. Electron World, 2016(11): 103-104. DOI: 10.19353/j.cnki.dzsj.2016.11.074 [43] 钟华强, 骆志平, 刘森林, 等. 基于PIN光电二极管的个人辐射探测器研制[J]. 原子能科学技术,2020,54(2):360-365. DOI: 10.7538/yzk.2019.youxian.0234 Zhong HQ, Luo ZP, Liu SL, et al. Development of radiation detector based on PIN photodiode[J]. At Energy Sci Technol, 2020, 54(2): 360-365. DOI: 10.7538/yzk.2019.youxian.0234