Simulation of mobile cone-beam CT imaging based on the Geant4/GATE platform
MING Xin1, WANG Yongjian1, ZHAI Hezheng2,3, YANG Chengwen4, MENG Huipeng5, YANG Jian6, BO Wenzhu6
1. Tianjin Medical University, Tianjin 300203 China; 2. Tianjin University, Tianjin 300072 China; 3. Institute of Radiation Medicine, Chinese Academy of Medical Sciences, Tianjin 300192 China; 4. Tianjin Medical University Cancer Hospital, Tianjin 300060 China; 5. Characteristic Medical Center of PAP, Tianjin 300162 China; 6. Tianjin Jinxi Medical Equipment Co., Ltd., Tianjin 300385 China
明鑫, 王涌鉴, 翟贺争, 杨成文, 孟慧鹏, 杨舰, 薄文柱. 基于Geant4/GATE平台模拟移动式锥形束CT成像[J]. 中国辐射卫生, 2021, 30(6): 706-709,719.
MING Xin, WANG Yongjian, ZHAI Hezheng, YANG Chengwen, MENG Huipeng, YANG Jian, BO Wenzhu. Simulation of mobile cone-beam CT imaging based on the Geant4/GATE platform. , 2021, 30(6): 706-709,719.
[1] Evans MRB, White P, Cowley P, et al. Revolution in acute ischaemic stroke care: a practical guide to mechanical thrombectomy[J]. Pract Neurol, 2017, 17(4): 252-265. DOI: 10.1136/practneurol-2017-001685 [2] 刘伟, 张倩, 陈思运, 等. 移动CT相对于传统CT存在的优势[J]. 生物医学工程与临床,2020,24(3):343-345. DOI: 10.13339/j.cnki.sglc.20200414.012 Liu W, Zhang Q, Chen SY, et al. Advantages of mobile CT over traditional CT[J]. Biomed Eng Clin Med, 2020, 24(3): 343-345. DOI: 10.13339/j.cnki.sglc.20200414.012 [3] 姜庆寰, 尉可道, 王建超, 等. 锥形束CT(CBCT)在医学实践中应用的进展[J]. 中国辐射卫生,2017,26(3):316-321. DOI: 10.13491/j.cnki.issn.1004-714X.2017.03.021 Jiang QH, Wei KD, Wang JC, et al. Progress of the application of cone beam computed tomography (CBCT) in medical practice[J]. Chin J Radiol Health, 2017, 26(3): 316-321. DOI: 10.13491/j.cnki.issn.1004-714X.2017.03.021 [4] 张伟欣. 基于MSCT及CBCT技术的便携式移动CT临床应用分析[J]. 生物医学工程学进展,2021,42(2):100-102. DOI: 10.3969/j.issn.1674-1242.2021.02.009 Zhang WX. Clinical application of portable mobile CT based on MSCT and CBCT technology[J]. Prog Biomed Eng, 2021, 42(2): 100-102. DOI: 10.3969/j.issn.1674-1242.2021.02.009 [5] 孟慧鹏, 王克强, 付娟, 等. 一种基于Monte Carlo模拟的锥形束CT图像散射校准方法[J]. 辐射研究与辐射工艺学报,2019,37(4):25-32. DOI: 10.11889/j.1000-3436.2019.rrj.37.040303 Meng HP, Wang KQ, Fu J, et al. Method of core-beam CT imaging scatter correction based on Monte Carlo simulations[J]. J Radiat Res Radiat Process, 2019, 37(4): 25-32. DOI: 10.11889/j.1000-3436.2019.rrj.37.040303 [6] Zhang YM, Chen YS, Zhong AN, et al. Scatter correction based on adaptive photon path-based Monte Carlo simulation method in Multi-GPU platform[J]. Comput Methods Programs Biomed, 2020, 194: 105487. DOI: 10.1016/j.cmpb.2020.105487 [7] Skaarup M, Edmund JM, Dorn S, et al. Dual-energy material decomposition for cone-beam computed tomography in image-guided radiotherapy[J]. Acta Oncol, 2019, 58(10): 1483-1488. DOI: 10.1080/0284186X.2019.1629010 [8] 中华人民共和国国家卫生健康委员会. WS 76—2020 医用X射线诊断设备质量控制检测规范[S]. 北京: 中国标准出版社, 2020. National Health Commission of the People’s Republic of China. WS 76—2020 Specification for testing of quality control in medical X-ray diagnostic equipment[S]. Beijing: Standards Press of China, 2020.