Measurement of dose field distribution around mobile cone beam computed tomography (CBCT)
ZONG Rui1, WANG Nan2, BO Wenzhu2, LIU Lei1, ZHAI Hezheng3,4, GAO Jie4, CAO Wentian5, YU Xinguang1, ZHAI Zipo6
1. General Hospital of People's Liberation Army, Beijing 100853 China; 2. Tianjin Jinxi Medical Equipment Co., Ltd., Tianjin 300385 China; 3. Tianjin University, Tianjin 300072 China; 4. Institute of Radiology, Chinese Academy of Medical Sciences, Tianjin 300110 China; 5. Peking University, Beijing 100871 China; 6. Hunan Prevention and Treatment Institute for Occupational Diseases, Changsha 410007 China
[1] 李文臣, 张晓红, 徐如祥, 等. 新型国产16层移动CT在颅脑创伤中的临床应用[J]. 中华神经创伤外科电子杂志,2019,5(1):11-14. DOI: 10.3877/cma.j.issn.2095-9141.2019.01.003 Li WC, Zhang XH, Xu RX, et al. Clinical application of novel 16-slice mobile CT head scan in traumatic brain injury[J]. Chin J Neurotraumatic Surg Electron Ed, 2019, 5(1): 11-14. DOI: 10.3877/cma.j.issn.2095-9141.2019.01.003 [2] John S, Stock S, Cerejo R, et al. Brain imaging using mobile CT: current status and future prospects[J]. J Neuroimaging, 2016, 26(1): 5-15. DOI: 10.1111/jon.12319 [3] Hov MR, Zakariassen E, Lindner T, et al. Interpretation of brain CT scans in the field by critical care physicians in a mobile stroke unit[J]. J Neuroimaging, 2018, 28(1): 106-111. DOI: 10.1111/jon.12458 [4] 国家卫生健康委员会. GBZ 130 —2020 放射诊断放射防护要求[S]. 北京: 中国标准出版社, 2020. National Health Commission. GBZ 130 —2020 Requirements for radiological protection in diagnostic radiology[S]. Beijing: Standard Press of China, 2020. [5] 杨新芳, 赵进沛, 刘士敏, 等. 一台新型移动式CT的放射防护监督监测[J]. 中国辐射卫生,2011,20(3):317. DOI: 10.13491/j.cnki.issn.1004-714x.2011.03.012 Yang XF, Zhao JP, Liu SM, et al. Radiation protection monitoring of a new mobile CT[J]. Chin J Radiol Health, 2011, 20(3): 317. DOI: 10.13491/j.cnki.issn.1004-714x.2011.03.012 [6] 陈飚, 陈春晖, 高林峰, 等. X射线床旁摄片场所电离辐射水平和防护效果研究[J]. 中国辐射卫生,2019,28(2):135-138. DOI: 10.13491/j.issn.1004-714x.2019.02.006 Chen B, Chen CH, Gao LF, et al. A field research on the ionizing radiation level and protective effect in X-ray bedside radiography[J]. Chin J Radiol Health, 2019, 28(2): 135-138. DOI: 10.13491/j.issn.1004-714x.2019.02.006 [7] 张金戈, 彭婉琳, 李真林, 等. 移动CT头部扫描辐射剂量场的空间分布[J]. 中华放射医学与防护杂志,2017,37(4):302-305. DOI: 10.3760/cma.j.issn.0254-5098.2017.04.014 Zhang JG, Peng WL, Li ZL, et al. Spatial distribution of radiation dose field from mobile CT head scanning[J]. Chin J Radiol Med Prot, 2017, 37(4): 302-305. DOI: 10.3760/cma.j.issn.0254-5098.2017.04.014 [8] 杨新芳, 张强, 赵进沛, 等. 移动CT扫描受检者敏感器官体表辐射剂量及辐射场分布与防护措施的研究[J]. 解放军医药杂志,2012,24(7):32-34. DOI: 10.3969/j.issn.2095-140X.2012.07.012 Yang XF, Zhang Q, Zhao JP, et al. Study on radiation dosage, distribution and protection measures of subjects' body surface at sensitive organs by mobile CT scanning[J]. Med Pharm J Chin People's Liberation Army, 2012, 24(7): 32-34. DOI: 10.3969/j.issn.2095-140X.2012.07.012 [9] 张连强, 陈基明. 移动CT概述[J]. 医疗卫生装备,2011,32(8):78-79. DOI: 10.3969/j.issn.1003-8868.2011.08.034 Zhang LQ, Chen JM. Summary of Mobile CT[J]. Chin Med Equip J, 2011, 32(8): 78-79. DOI: 10.3969/j.issn.1003-8868.2011.08.034 [10] 龚佩佩, 姚麒, 刘倩倩, 等. 移动CT在神经外科重症监护病房应用中的特点分析[J]. 南通大学学报(医学版),2016,36(5):401-403. DOI: 10.16424/j.cnki.cn32-1807/r.2016.05.009 Gong PP, Yao Q, Liu QQ, et al. Characteristics of mobile CT in neurosurgical intensive care unit[J]. J Nantong Univ Med Sci, 2016, 36(5): 401-403. DOI: 10.16424/j.cnki.cn32-1807/r.2016.05.009 [11] 路伟, 王兴功, 陈基明, 等. 新型医用移动式CT的质量保证和放射防护研究[J]. 中国辐射卫生,2013,22(1):53-55. DOI: 10.13491/j.cnki.issn.1004-714x.2013.01.030 Lu W, Wang XG, Chen JM, et al. Study on quality assurance and radiation protection of new medical mobile CT[J]. Chin J Radiol Health, 2013, 22(1): 53-55. DOI: 10.13491/j.cnki.issn.1004-714x.2013.01.030 [12] 赵进沛, 杨新芳, 李秀芹, 等. 小型移动式CT设备及其辐射防护分析[J]. 灾害医学与救援(电子版), 2012, 1(2): 94-96.DOI:CNKI:SUN:ZAIY.0.2012-02-008. Zhao JP, Yang XF, Li XQ, et al. Small mobile CT equipment and its radiation protection analysis[J]. Disaster Med Rescue Electron Ed, 2012, 1(2): 94-96.DOI:CNKI:SUN:ZAIY.0.2012-02-008. [13] 姚杰, 高林锋, 钱爱君, 等. 头颈部、胸部CT扫描频次分布及其剂量水平研究[J]. 中国辐射卫生,2020,29(4):339-344. DOI: 10.13491/j.issn.1004-714X.2020.04.005 Yao J, Gao LF, Qian AJ, et al. Research on frequency distribution and dose levels of head, neck, chest CT scans[J]. Chin J Radiol Health, 2020, 29(4): 339-344. DOI: 10.13491/j.issn.1004-714X.2020.04.005 [14] 翟贺争, 杜仲庆, 吴香君, 等. 2016—2018年参加全国个人剂量监测能力考核结果分析[J]. 中国辐射卫生,2020,29(1):45-48. DOI: 10.13491/j.issn.1004-714X.2020.01.010 Zhai HZ, Du ZQ, Wu XJ, et al. Comparison and analysis of the intercomparison results of national personal dose monitoring from 2016 to 2018[J]. Chin J Radiol Health, 2020, 29(1): 45-48. DOI: 10.13491/j.issn.1004-714X.2020.01.010 [15] 侯慧玉, 陈少鹏, 任静, 等. 2015—2019年某医院放射人员个人剂量监测结果分析[J]. 中国辐射卫生,2020,29(4):370-373. DOI: 10.13491/j.issn.1004-714X.2020.04.012 Hou HY, Chen SP, Ren J, et al. Surveillance results and analysis of radiation individual doses in a hospital from 2015 to 2019[J]. Chin J Radiol Health, 2020, 29(4): 370-373. DOI: 10.13491/j.issn.1004-714X.2020.04.012 [16] 国家质量监督检验检疫总局. GB 18871—2002 电离辐射防护与辐射源安全基本标准[S]. 北京: 中国标准出版社, 2002. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. GB 18871—2002 Basic standards for protection against ionizing radiation and for the safety of radiation sources[S]. Beijing: Standard Press of China, 2002.