何栋成, 张晓晔, 张艳, 韩济华, 曹磊, 朱志坚. ArcCheck剂量验证角度分析食管上段癌调强放疗技术[J]. 中国辐射卫生, 2019, 28(2): 206-208,213.
HE Dongcheng, ZHANG Xiaoye, ZHANG Yan, HAN Jihua, CAO Lei, ZHU Zhijian. The analysis of the radiotherapy techniques for the treatment of upper esophageal cancer form the dose verification by ArcCheck. , 2019, 28(2): 206-208,213.
[1] 谷铣之,殷蔚伯,余子豪.肿瘤放射治疗学[M].北京:中国协和医科大学出版社,2008,546-574. [2] Chandra A, Guerrero T M, Liu H H, et al. Feasibility of using intensity-modulated radiotherapy to improve lung sparing in treatment planning for distal esophageal cancer[J]. Radiother Oncol, 2005, 77(3):247-253. [3] Fenkell L, Kaminsky I, Breen S, et al. Dosimetric comparison of IMRT vs. 3D conformal radiotherapy in the treatment of cancer of the cervical esophagus[J].Radiother Oncol, 2008, 89(3):287-291. [4] Nutting C M, Bedford J L,Cosgrove V P, et al. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy[J].Radiother Oncol, 2001, 61(2):157-163. [5] 章敏娟.调强射野的实现方式研究[D].南京:东南大学,2007,14-19. [6] 胡逸民.肿瘤放射物理学[M].北京:原子能出版社,1999,550-559. [7] 李军,张西志,张先稳,等.Varian 医用直线加速器 DMLC 物理参数的测量与验证[J].北京生物医学工程,2015,34(5):509-513. [8] Yu C X. Intensity-modulated arc therapy with dynamic multi-leaf collimation:an alternative to tomotherapy[J]. Phys Med Biol, 1995, 40(9):1435-1449. [9] 张晶,王智勇,侯宁,等.上段食管癌旋转容积调强放射治疗计划的验证分析[J].现代医学与健康研究,2018,2(6):74. [10] 孔燕,孔栋,魏贤顶,等.调强计划验证中MatriXX电离室的角度响应修正[J].中国辐射卫生,2016,25(4):398-400,405. [11] 李成强,李光俊,冀传仙,等.ArcCHECK 半导体探头特性及在容积调强弧形治疗剂量验证应用研究[J].中华放射肿瘤学杂志,2013,22(3):253-257. [12] 戴越,胡春红,李小东,等.MatriXX 两种调强放疗剂量验证方法的比较分析[J].中华放射肿瘤学杂志,2013,22(4):312-314. [13] 张俊俊,邱小平,李奇欣,等.ArcCheck系统在鼻咽癌容积旋转调强剂量验证中的应用[J].中国医学物理学杂志,2014,31(5):5136-5137. [14] Chen H X, Lohr F, Fritz P, et al. Stereotactic, single-dose irradiation of lung tumors:a comparison of absolute dose and dose distribution between pencil beam and Monte Carlo algorithms based on actual patient CT scans[J]. Int J Radiat Oncol Biol Phys, 2010, 78(3):955-963. [15] 徐洋洋,邓磊,杨亚新,等.放射治疗外照射的蒙特卡罗计算[J].中国辐射卫生,2016,25(1):15-17. [16] 何方方,刘主龙.蒙特卡罗技术在光子和电子放射治疗中提高速度的进展[J].中国辐射卫生,2015,24(3):314-316. [17] Wagner D, christiansen H, Wolff H, et al. Radiotherapy of malignant gliomas:comparison of volumetric single arc technique (RapidArc), dynamic intensity-modulated technique and 3D conformal technique[J].Radiother Oncol, 2009, 93 (3):593-596. [18] Clivio A, Fogliata A, Franzetti-Pellanda A, et al.Volumetric-modulated arc radiotherapy for carcinomas of the anal canal:A treatment planning comparison with fixed field IMRT[J]. Radiother Oncol, 2009,92 (1):118-124. [19] 张瑞,习勉,李巧巧,等.胸上段食管癌容积旋转调强和静态调强与三维适形放疗计划的剂量学比较[J].中山大学学报(医学科学版),2012,33(2):260-264.