The protective efficiency of different materials and the effect on the imaging quality of CT scanning
WANG Qian1, FENG Shichao1, LIANG Yuan1, MA Xiaohong1, ZHAO Xinming1, LIU Xia2, QI Weiwei2
1. National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021 China; 2. Peking University People's Hospital
王倩, 冯世超, 梁媛, 马霄虹, 赵心明, 刘霞, 綦维维. CT扫描野内表面防护不同材料的防护效果以及对图像质量的影响[J]. 中国辐射卫生, 2018, 27(2): 173-177.
WANG Qian, FENG Shichao, LIANG Yuan, MA Xiaohong, ZHAO Xinming, LIU Xia, QI Weiwei. The protective efficiency of different materials and the effect on the imaging quality of CT scanning. , 2018, 27(2): 173-177.
[1] T. Kubo, Y. Ohno, H. U. Kauczor, et al. Radiation dose reduction in chest CT-review of available options[J]. Eur J Radiol, 2014, 83(10), 1953-1961. [2] S. Safiullah, R. Patel, B. Uribe, et al. Prevalence of Protective Shielding Utilization for Radiation Dose Reduction in Adult Patients Undergoing Body Scanning Using Computed Tomography[J]. J Endourol,2017, 31(10), 985-990. [3] C. Hohl, J. E. Wildberger, C. Suss, et al. Radiation dose reduction to breast and thyroid during MDCT:effectiveness of an in-plane bismuth shield[J]. Acta Radiol,2006, 47(6):562-567. [4] Y. H. Lee, E. T. Park, P. K. Cho, et al. Comparative analysis of radiation dose and image quality between thyroid shielding and unshielding during CT examination of the neck[J]. AJR Am J Roentgenol,2011, 196(3):611-615. [5] Kalra MK,Maher MM,Sahani DV,et al.Low-dose CT of the abdomen:evaluation of image improvement with use of noise reduction filters pilot study[J].Radiology,2003,228(1):251-256. [6] D. Y. Shamoun, Linear No-Threshold model and standards for protection against radiation[J]. Regul Toxicol Pharmacol,2016, 77:49-53. [7] 陈邦文,杨爱春,何海青.CT检查中的辐射剂量及其防护对策[J].中国辐射卫生,2009,18(04):445-446. [8] 图布扎雅.患者CT检查非检查部位放射防护的价值和意义[J].世界最新医学信息文摘, 2017,17(32):108. [9] 杨爱春,陈邦文,何海青.重视CT检查中儿童的辐射防护[J].中国辐射卫生, 2010, 19(02):168-169. [10] 孙振学,邸茹杰,于显钊,等.高端影像学检查CT辐射的安全认知和意识水平调查[J].武警医学, 2017, 28(07):730-732. [11] J. W. Lambert, R. G. Gould, Evaluation of a Net Dose-Reducing Organ-Based Tube Current Modulation Technique:Comparison With Standard Dose and Bismuth-Shielded Acquisitions[J]. AJR Am J Roentgenol,2016, 206(6):1233-1240. [12] 刘平,喻崇容, 向东生,等.护技配合做好胸部CT扫描与辐射防护的探讨[J].中华肺部疾病杂志, 2017, 10(04):478-479. [13] 胡军武,邹乾.CT质量控制与放射防护分析[J].影像研究与医学应用, 2017, 1(8):173-174. [14] M. Hajiha and D. D. Baldwin, Editorial Comment on:Prevalence of Protective Shielding Utilization for Radiation Dose Reduction in Adult Patients Undergoing Body Scanning Using Computed Tomography by Safiullah et al[J].J Endourol, 2017, 31(10):991. [15] 杨珂,柳怡,张巍,等.山东省CT检查防护水平及其影响因素[J].中国辐射卫生,2016,25(03):316-318.