熊文俊, 颜强, 王莹, 黄金峰, 钟华强. 基于碲锌镉探测器的便携式核素识别仪研制[J]. 中国辐射卫生, 2023, 32(4): 387-392.
XIONG Wenjun, YAN Qiang, WANG Ying, HUANG Jinfeng, ZHONG Huaqiang. Development of a portable radiation detector for nuclide identification based on CdZnTe. Chinese Journal of Radiological Health, 2023, 32(4): 387-392.
[1] 王莹, 熊文俊, 骆志平, 等. 基于半球型碲锌镉探测器的多功能剂量率仪适用性研究[J]. 原子能科学技术,2014,48(S1):618-622. DOI: 10.7538/yzk.2014.48.S0.0618 Wang Y, Xiong WJ, Luo ZP, et al. Capability study of multi-function dose rate meter based on hemisphere CdZnTe detector[J]. At Energy Sci Technol, 2014, 48(S1): 618-622. DOI: 10.7538/yzk.2014.48.S0.0618 [2] 曾国强, 张开琪, 范颖, 等. 共面栅碲锌镉探测器读出电路设计及性能研究[J]. 原子能科学技术,2018,52(3):539-546. DOI: 10.7538/yzk.2017.youxian.0383 Zeng GQ, Zhang KQ, Fan Y, et al. Design and performance of readout circuit for Coplanar gate CdZnte detector[J]. At Energy Sci Technol, 2018, 52(3): 539-546. DOI: 10.7538/yzk.2017.youxian.0383 [3] 花锋, 席守智, 李明旭, 等. 低能量宽量程碲锌镉探头研制[J]. 核电子学与探测技术,2021,41(4):687-691. DOI: 10.3969/j.issn.0258-0934.2021.04.027 Hua F, Xi SZ, Li MX, et al. Preparation and study of low energy and wide dose range probe based on the CZT[J]. Nucl Electron Detect Technol, 2021, 41(4): 687-691. DOI: 10.3969/j.issn.0258-0934.2021.04.027 [4] 方登富, 韦应靖, 崔伟, 等. 基于NaI(Tl)γ能谱温漂修正方法研究[J]. 中国辐射卫生,2021,30(1):19-23, 33. DOI: 10.13491/j.issn.1004-714X.2021.01.005 Fang DF, Wei YJ, Cui W, et al. Research on temperature peak-shift correction methods for NaI(TI) gamma spectrum[J]. Chin J Radiol Health, 2021, 30(1): 19-23, 33. DOI: 10.13491/j.issn.1004-714X.2021.01.005 [5] 樊瑞睿, 刘雅清, 孟祥承. 用上升沿甄别技术修正碲锌镉探测器的能量分辨率[J]. 现代应用物理,2020,11(4):31-35. DOI: 10.12061/j.issn.2095-6223.2020.040202 Fan RR, Liu YQ, Meng XC. Energy resolution correction of CdZnTe detector with rise time discrimination technique[J]. Mod Appl Phys, 2020, 11(4): 31-35. DOI: 10.12061/j.issn.2095-6223.2020.040202 [6] 黄金峰, 王莹, 熊文俊, 等. 基于Monte-Carlo模拟和峰形拟合的CdZnTe探测器 G (E)函数简便计算方法研究[J]. 原子能科学技术,2017,51(1):165-169. DOI: 10.7538/yzk.2017.51.01.0165 Huang JF, Wang Y, Xiong WJ, et al. Study on simple G (E) function calculation method of CdZnTe detector based on Monte-Carlo method and peak shape fitting[J]. At Energy Sci Technol, 2017, 51(1): 165-169. DOI: 10.7538/yzk.2017.51.01.0165 [7] Taulbee TD, McCartney KA, Traub R, et al. Implementation of ICRP 116 dose conversion coefficients for reconstructing organ dose in a radiation compensation program[J]. Radiat Prot Dosim, 2017, 173(13): 131-137. DOI: 10.1093/rpd/ncw305 [8] 李兴隆, 王薇, 吴建华, 等. 用于康普顿相机的成像探测系统研制[J]. 中国辐射卫生,2020,29(5):519-523, 529. DOI: 10.13491/j.issn.1004-714X.2020.05.019 Li XL, Wang W, Wu JH, et al. Development of detection system for Compton camera[J]. Chin J Radiol Health, 2020, 29(5): 519-523, 529. DOI: 10.13491/j.issn.1004-714X.2020.05.019 [9] 谢占军. 碲锌镉探测器加权积分法测量周围剂量当量[D]. 南宁: 广西大学, 2008. Xie ZJ. CZT detector weighted integration method for measuring ambient dose equivalent[D]. Nanning: Guangxi University, 2008. [10] 曹勤剑, 夏三强, 贺萌, 等. 基于溴化镧探测器的γ射线空气吸收剂量率的测量方法[J]. 中国辐射卫生,2021,30(2):154-158. DOI: 10.13491/j.issn.1004-714X.2021.02.007 Cao QJ, Xia SQ, He M, et al. The measurement method of gamma ray air absorbed dose rate based on LaBr3(Ce)detector[J]. Chin J Radiol Health, 2021, 30(2): 154-158. DOI: 10.13491/j.issn.1004-714X.2021.02.007 [11] Borella A, Bruggeman M, Rossa R, et al. Peak shape characterization of a 500 mm3 cadmium zinc telluride detector and analysis of spectroscopic measurement data for uranium samples[J]. J Nucl Mater Manage, 2021, 49(3): 75-83 [12] 唐生达, 兰长林, 聂阳波, 等. Cs26LiYCl6: Ce探测器γ响应函数的高斯展宽及解谱研究[J]. 现代应用物理,2021,12(4):20-26. DOI: 10.12061/j.issn.2095-6223.2021.040201 Tang SD, Lan CL, Nie YB, et al. Gaussian broadening of γ response function and spectrum resolution for Cs26LiYCl6: Ce detector[J]. Mod Appl Phys, 2021, 12(4): 20-26. DOI: 10.12061/j.issn.2095-6223.2021.040201 [13] 王莹珏, 刘超, 郑玉来, 等. 核反恐下基于碲锌镉(CZT)探测器便携式谱仪的研制[J]. 同位素,2021,34(3):195-200. DOI: 10.7538/tws.2021.34.03.0195 Wang YJ, Liu C, Zheng YL, et al. Development of portable spectrometer based on CZT detector under nuclear anti-terrorism[J]. J Isot, 2021, 34(3): 195-200. DOI: 10.7538/tws.2021.34.03.0195 [14] 王凯, 张伟, 李航. 事故后应急谱仪的研制[J]. 中国辐射卫生,2016,25(3):356-360. DOI: 10.13491/j.cnki.issn.1004-714X.2016.03.036 Wang K, Zhang W, Li H. The development of emergency response spectrometer[J]. Chin J Radiol Health, 2016, 25(3): 356-360. DOI: 10.13491/j.cnki.issn.1004-714X.2016.03.036